RV Products Airxcel Chillgrille 8330 634 Series Installation Instructions Manual

Coleman-mach air conditioners

Advertisement

RV Products Division
INSTALLATION INSTRUCTIONS
FOR
8330*63(3,4)* COOL ONLY A/C
8330*635* HEAT READY A/C
8530*63** HEAT PUMP
CHILLGRILLE™
FLUSH MOUNT CEILING ASSEMBLY
DESIGNED AND MANUFACTURED BY THE MAKERS OF
COLEMAN®-MACH® AIR CONDITIONERS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Airxcel Chillgrille 8330 634 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RV Products Airxcel Chillgrille 8330 634 Series

  • Page 1 RV Products Division INSTALLATION INSTRUCTIONS 8330*63(3,4)* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE™ FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN®-MACH® AIR CONDITIONERS...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Warnings ............Package Contents .
  • Page 3: General Information

    GENERAL INFORMATION The flush mount ceiling plenum is designed for application in All air conditioning equipment is subject to freeze up when systems that utilize field fabricated (OEM supplied) cold air evaporator air flow is sufficiently reduced. Ducting of any ducting.
  • Page 4: Supply Ducting And Registers

    Plenum Thermostat Function Of Low Voltage Terminal Terminal Wire Extending From Ceiling Plenum Designation Connection BLUE Completes -12 VDC circuit for all relays “Cool Only” YELLOW Energizes coil on Compressor Relay “Heat Ready” Boxes GREEN Energizes coil on High Fan Relay Boxes GRAY Energizes coil on Low Fan Relay...
  • Page 5: Routing Thermostat Wiring

    FIGURE 1 ROUTING THERMOSTAT WIRING Following the instructions packed with the Two wires are required: thermostat, determine a location for the thermostat mounting. One supply lead must be +12 VDC and red in color. Following Airxcel, Inc. low voltage wiring specifications and all local and national electrical The second supply lead must be -12 VDC codes: For 12 VDC thermostats, it is required that...
  • Page 6: Routing 115 Vac Wiring

    Four (4) wires are required (5 wires for Airxcel, Inc. low voltage wiring specifications: heat/cool boxes). These wires are as follows: All low voltage wiring should be 18 gauge minimum. Blue wire for -12 VDC circuit Yellow wire for compressor circuit Low voltage wiring must be routed into the Green wire for high fan circuit front side of the ceiling plenum opening.
  • Page 7: Connect 115 Vac Wiring

    (O N SO ME UNITS, THERE W ILL BE MACHINE SCREW S AT THESE LOCATIO NS) FIGURE 2 CONNECT 115 VAC WIRING WARNING – SHOCK HAZARD DANGER To prevent the possibility of severe personal WHEN USING NON-METALLIC SHEATH injury or equipment damage due to electrical SUPPLY CABLES (ROMEX, ETC.), STRIP shock, always be sure the electrical power is SHEATH BACK TO EXPOSE 4-6 INCHES...
  • Page 8: Connect Thermostat Wiring

    IF OTHER THAN NON-METALLIC DANGER CABLES ARE USED FOR SUPPLY CONDUCTORS, APPROPRIATE STRAIN TO PREVENT THE POSSIBILITY OF SHOCK INJURY RELIEF CONNECTORS OR CLAMPS FROM APPLIANCE OPERATION: SHOULD BE USED. THE WHITE WIRE MUST BE CONNECTED TO IN NO CASE SHOULD CLAMPING OR NEUTRAL IN THE SERVICE BOX ENTRANCE AND PINCHING ACTION BE APPLIED TO THE MECHANICAL GROUND MUST BE...
  • Page 9: Install Air Grille Assembly

    TIE ALL WIRING TO INSURE NO CONTACT WITH THE HEATER OR ANY SHARP EDGES.           KEEP IN MIND THAT HIGH VELOCITY AIR WILL BE ENCOUNTERED IN THIS AREA.                  FIGURE 4 Basepan...