  • Page 1 DS8150 Chair Scale User Manual MAN0301 – Rev 1 Doran Scales, Inc. www.doranscales.com...
  • Page 2: Table Of Contents

    Section 1. Unpacking and Installation ............1 Introduction ........................1 Unpacking ........................1 Cautions and Warnings ....................1 Care & Cleaning ......................1 Section 2. Battery Operation ..............2 Section 3. Scale Operation ............... 3 Display Pushbuttons ..................... 3 Display Annunciators ....................4 Weighing a Patient ......................
  • Page 3: Section 1. Unpacking And Installation

    Section 1. Unpacking and Installation Introduction Thank you for purchasing a Doran scale. This product has been designed with the highest level of technology. We are dedicated to delivering a superior product that will provide many years of trouble free service.
  • Page 4: Section 2. Battery Operation

    Section 2. Battery Operation Battery Installation The indicator comes with a set of six AA alkaline batteries. These batteries can perform over 85,000 weighments of typical use with the standard Automatic Shutoff Timer settings. The battery compartment is located on the backside of the indicator. Press locking tab up to release battery compartment cover.
  • Page 5: Section 3. Scale Operation

    Section 3. Scale Operation Fig. 3 Front Panel Display Pushbuttons The Model DS8150 controls consist of Units, Zero, Reweigh, ▲, ▼, and BMI buttons. The display is used to provide weight indications and operator messages indicating scale operation. Power On/Off Press the Zero button to turn on the indicator.
  • Page 6: Display Annunciators

    be locked or unlocked by pressing and holding Units for 5 seconds. An “L on“ message is displayed when button is locked and “L off“ when unlocked. Reweigh To reinitiate the weighing process, press Reweigh. This will allow a new measurement to be taken without the patient having to leave the chair.
  • Page 7 Battery Indicator The battery indicator displays the remaining battery life available. See the battery operation section for detailed information. NOTE: Battery Indicator will be disabled when using an external power supply. Software Number and Revision display Pressing and holding the Reweigh button for 3 seconds will perform a display test, show the Software number “Su179”...
  • Page 8: Weighing A Patient

    Weighing a Patient 1. Lock all four wheels on chair scale. 2. Turn on the indicator by pressing the Zero button. 3. The indicator will perform a startup zero. 4. The indicator will momentarily display dashes, “-----”, followed by 0.0. 5.
  • Page 9: Section 4. Specifications

    Section 4. Specifications Chair Dimensions 36” L x 27” W x 44” H Indicator Dimensions 8” L x 6.5” W x 2.3” H Power 12VDC AC Adapter (Negative Center) Optional: 6 AA Alkaline Batteries Displayed Units lb, kg Capacity 550 x 0.2 lb or 250 x 0.1 kg Construction Painted Mild Steel and Plastic Housing.
  • Page 10: Section 5. Troubleshooting

    Section 5. Troubleshooting General Problem Resolution Problem What to Do or Check Weight reading will not repeat or Person or object other than that being scale does not return to zero when weighed is touching the scale. weight is removed. Verify that there is nothing caught in or interfering with the seat.
  • Page 11 Doran Scales, Inc. 883 Enterprise Court St. Charles, IL 60174 www.doranscales.com 630-879-1200...

Table of Contents