7. Cleaning

1. CLEANING VALVE WITH CLEANING AGENTS:
- Use authorised personnel to clean the valve.
- Observe concentrations of cleaning agents.
- Follow instructions of cleaning agent suppliers.
- Always use protective goggles and gloves.
BURN RISK
2. HOT VALVE/PIPING:
- Never touch hot valve or piping, if possible.
- Alternatively use protective gloves.
Step
First rinsing
Washing
Intermediate washing
Washing
Final rinsing
Recommended claning speed = 2 m/s
The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
Risk of
corrosion
stainless steel
3. HANDLING OF CLEANING AGENTS:
- Dose cleaning agents regularly to avoid excessive concentration.
- Always rinse carefully with clean water after cleaning.
- Check compatibility of valve matter.
Example of suggested CIP
Temperature °C
Atmosphere
70°
Atmosphere
70°
Atmosphere
Risk of
seal
damage
Cip product
Water without chlorine or
chlorids
Soda (NaOH) at 1%
Water without chlorine or
chlorids
Nitric acid (HNO3) at 0,5%
Water without chlorine or
chlorids
(GB-IST-B925-0910) 9/35