  • Page 1 INSTRUCTION MANUAL BBZO BBZOG pneumatic tank bottom valve BBZOH BBZOR pneumatic long stroke tank bottom valve GB-IST-BBZO-0413...
  • Page 2: Table Of Contents

    The data and information in this instruction manual are subject to modifications or updates without any further notice or obligations on the part of the manufacturer. (GB-IST-BBZO-0413) 2/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 3: Safety Signs

    NEVER remove a valve from piping or disassemble it when the valve or piping are pressurised. We cannot be held responsible for correct installation, operation and maintenance! (GB-IST-BBZO-0413) 3/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 4: Receiving/Unpacking/Storage

    Avoid vibration. dispose of according to Use current claim procedure if Min.: - 10 °C current directives. necessary. Max.: + 50 °C (GB-IST-BBZO-0413) 4/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 5: Installation

    5. CORRECT FLOW DIRECTION: COMPENSATE FOR: If possible, have flow against valve closing direction Vibration to avoid or minimise water hammer. Thermal expansion (GB-IST-BBZO-0413) 5/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 6 BBZOH BBZOR (with Giotto-Top ® Dimenson Valve (mm) DN65 DN80 DN100 DN125 DN150 8. INSTALLING VALVE INTO PIPING: Ensure sufficient clearance for valve disassembly. (GB-IST-BBZO-0413) 6/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 7: Operation

    BBZO: Bottom tank piping, if possible. BBZOG: Bottom tank Alternatively use protective BBZOH: Long stroke Bottom tank gloves. BBZOR: Long stroke Bottom tank (GB-IST-BBZO-0413) 7/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 8: Troubleshooting

    (NC) or vice versa Dirt in actuator Check and service actuator Incorrect positioning of valve body Disassemble and repositiopn valve body (GB-IST-BBZO-0413) 8/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 9: Cleaning

    Washing 70° Nitric acid (HNO3) at 0,5% Water without chlorine or Final rinsing Atmosphere chlorids Recommended claning speed = 2 m/s (GB-IST-BBZO-0413) 9/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 10: General Maintenance

    Always release fluid pressure from valve and piping Never touch hot valve or piping, if possible. before disassembling the valve. Alternatively use protective gloves. (GB-IST-BBZO-0413) 10/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 11: Planned Maintenance

    Check for correct operation and Check the correct operation absence of leakage and absence of leakage Periodical Record all actions taken Record all actions taken (GB-IST-BBZO-0413) 11/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 12: Spare Parts Ordering

    Month/Year of purchase: Shipping instructions: Quantity: Position no.: Description: Quantity: Position no.: Description: Quantity: Position no.: Description: Quantity: Position no.: Description: (GB-IST-BBZO-0413) 12/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 13: Disassembly Bbzo / Bbzor

    5b. P.T.F.E. SHUTTER - Unscrew the shutter nut (28) and shutter (2). remove the sealing ring (14) from the shutter (2). (GB-IST-BBZO-0413) 13/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 14 9. Remove screws M6x10 and guide bushing from the cylinder (17) with a suitable assembly (35). tool. Remove seal rings (277 e 276). (GB-IST-BBZO-0413) 14/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 15: Drawings Bbzo / Bbzor

    11. Disassembly of BBZO / BBZOR BBZO BBZOR P.T.F.E. SHUTTER (GB-IST-BBZO-0413) 15/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 16: Assembly Of Bbzo / Bbzor

    6. Insert the clamp (33) between the lower body (1) and the assembly (35). cylinder (9). (GB-IST-BBZO-0413) 16/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice. *Lubricate elastomers with a product suitable for food contact...
  • Page 17 Assemble the lower body (1) to the flange (100) using ve 2 M6x10 to allow assembly of the Giotto-Top the clamp (33). ® (GB-IST-BBZO-0413) 17/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 18: Disassembly Bbzog / Bbzoh

    (156 e 157) and the guide the cylinder (17) with a suitable tool. Remove bushing (120). seal rings (277 e 276). assembly (35) (GB-IST-BBZO-0413) 18/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 19: Drawings Bbzog / Bbzoh

    13. Disassembly of BBZOG / BBZOH BBZOG BBZOH P.T.F.E. SHUTTER (GB-IST-BBZO-0413) 19/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 20: Assembly Of Bbzog / Bbzoh

    7. Supply air to fitting (24). pivot with an allen wrench. der (9). (GB-IST-BBZO-0413) 20/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice. Counterhold! *Lubricate elastomers with a product suitable for food contact...
  • Page 21 8. Supply air to ve 2 M6x10 to allow assembly of the Giotto-Top sembly (35) with clamp (33). ® fitting (24). Counterhold! Counterhold! (GB-IST-BBZO-0413) 21/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 22: Parts List

    Socket screw Assembly Plug Flange Guide bushing Seal ring Seal ring Seal ring Seal ring Seal ring Seal ring Seal ring (GB-IST-BBZO-0413) 22/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 23: Technical Data

    - For fl uids in Group 1 with a DN greater than 25 - Valve size DN125 only for fl uids in Group 2 (GB-IST-BBZO-0413) 23/24 The Company BARDIANI VALVOLE reserves the right to modify its products at any time without prior notice.
  • Page 24: Warranty

    12 (twelve) months from the date of delivery. Notification of any product defects and/or faults must be sent in writing to Bardiani Valvole S.p.A. within 8 (eight) days of coming to light, providing adequate documentation of the defect/fault encountered can be provided as evidence.