Autonics TK Series User Manual
Standard type temperature controller
Hide thumbs
Also See for TK Series
:
User manual
(124 pages)
,
Communications manual
(38 pages)
,
User manual for communication
(26 pages)
1
2
3
4
5
Table Of Contents
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
page
of
24
Go
/
24
Contents
Table of Contents
Bookmarks
Table of Contents
Preface
User Manual Guide
Communication Protocol
Table of Contents
Modbus RTU Protocol
Read Coil Status(Func01-01H)
Read Input Status(Func02-02H)
Read Holding Registers(Func03-03H)
Read Input Registers(Func04-04H)
Preset Single Registers(Func06-06H)
Preset Multiple Registers(Func16-10H)
Exception Response-Error Code
Modbus Mapping Table
Read Coils(Func01) / Write Single Coil (Func05)
Read Discrete Inputs(Func02)
Read Input Registers(Func04)
Read Holding Register(Func03) / Write Single Register(Func06) / Write Multiple Registers(Func16)
Parameter 0 Setting Group[Func: 03/06/16, RW: R/W]
Parameter 1 Setting Group [Func: 03/06/16, RW: R/W]
Parameter 2 Setting Group [Func: 03/06/16, RW: R/W]
Parameter 3 Setting Group [Func: 03/06/16, RW: R/W]
Parameter 4 Setting Group [Func: 03/06/16, RW: R/W]
Parameter 5 Setting Group [Func: 03/06/16, RW: R/W]
Advertisement
Quick Links
Download this manual
USER MANUAL
For COMMUNICATION
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the TK Series and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Autonics TK Series
Controller Autonics TK series User Manual
High accuracy standard temperature controller (124 pages)
Controller Autonics TK Series Communications Manual
High accuracy standard temperature controllers (38 pages)
Temperature Controller Autonics TK Series User Manual
High accuracy standard (28 pages)
Temperature Controller Autonics TK Series User Manual For Communication
Standard type (26 pages)
Temperature Controller Autonics TK Series Product Manual
Simultaneous heating&cooling output pid temperature controllers (6 pages)
Temperature Controller Autonics TK4S User Manual
Standard type temp controller tk series (122 pages)
Temperature Controller Autonics TK4N Manual
Tk4 series (2 pages)
Temperature Controller Autonics TK4N Instruction Manual
High accuracy pid temperature controller (2 pages)
Temperature Controller Autonics TM Series User Manual
Multi-channel modular temperature controller (98 pages)
Temperature Controller Autonics TM Series User Manual For Communication
Multi-ch modular type temperature controller (36 pages)
Temperature Controller Autonics TX Series User Manual For Communication
(25 pages)
Temperature Controller Autonics TM-Q02H Technical Support Manual
Multi-ch modular type (26 pages)
Temperature Controller Autonics TR1D Series User Manual
(24 pages)
Temperature Controller Autonics TR1D Series Manual
Independent single display pid temperature controllers (6 pages)
Temperature Controller Autonics TMH Series Quick Start Manual
Modular2/4-channel pid temperature controllers with screw connector (6 pages)
Temperature Controller Autonics TN Series Product Manual
Two-degree-of-freedom pid temperature controllers (6 pages)
Summary of Contents for Autonics TK Series
Page 1
USER MANUAL For COMMUNICATION...
Page 2
© Copyright Reserved Autonics Co., Ltd.
Page 3: Preface
Preface Preface Thank you for purchasing an Autonics product. Please store this manual in a place where user can find easily, because it contains the guidance for the product and how to correctly use it. © Copyright Reserved Autonics Co., Ltd.
Page 4: User Manual Guide
The manual's content may vary depending on changes to the product's software and other unforeseen developments within Autonics, therefore, the contents of this manual is subject to change without prior notice. © Copyright Reserved Autonics Co., Ltd.
Page 5: Communication Protocol
Communication Protocol Communication Protocol TK Series is accepted to Modbus RTU Protocol. Users should be aware that it does not support a broadcast command. © Copyright Reserved Autonics Co., Ltd.
Page 6: Table Of Contents
Parameter 2 Setting Group [Func: 03/06/16, RW: R/W] ......19 2.4.4 Parameter 3 Setting Group [Func: 03/06/16, RW: R/W] ......20 2.4.5 Parameter 4 Setting Group [Func: 03/06/16, RW: R/W] ......21 2.4.6 Parameter 5 Setting Group [Func: 03/06/16, RW: R/W] ......22 © Copyright Reserved Autonics Co., Ltd.
Page 7: Modbus Rtu Protocol
OFF-ON-ON-OFF-ON” and the values of Coil 000010(0009 H)~000009(0008 H) are “OFF-ON”. Response(Slave Side) Error Check(CRC16) Data Data Slave Address Function Byte Count (000008~000001) (000010~000009) High 11 H 01 H 02 H CD H 01 H ## H ## H © Copyright Reserved Autonics Co., Ltd.
Page 8: Read Input Status(Func02-02H)
OFF-ON-ON-OFF-ON” and the values of 100010(0009 H)~100009(0008 H) are “OFF-ON”. Response(Slave Side) Error Check(CRC16) Data Data Slave Address Function Byte Count (000008~000001) (000010~000009) High 11 H 02 H 02 H CD H 01 H ## H ## H © Copyright Reserved Autonics Co., Ltd.
Page 9: Read Holding Registers(Func03-03H)
“555(22B H)” and “100(64 H)”. Response(Slave Side) Data Data Error Check(CRC16) Slave Address Function Byte Count High High High 11 H 03 H 04 H 02 H 2B H 00 H 64 H ## H ## H © Copyright Reserved Autonics Co., Ltd.
Page 10: Read Input Registers(Func04-04H)
“20(14 H)”. Response(Slave Side) Data Data Error Check(CRC16) Slave Address Function Byte Count High High High 11 H 04 H 04 H 00 H 0A H 00 H 14 H ## H ## H © Copyright Reserved Autonics Co., Ltd.
Page 11: Preset Single Registers(Func06-06H)
## H ## H Response(Slave Side) Starting Address Preset Data Error Check(CRC16) Slave Address Function High High High 11 H 06 H 00 H 00 H 00 H 0A H ## H ## H © Copyright Reserved Autonics Co., Ltd.
Page 12: Preset Multiple Registers(Func16-10H)
PLC, Graphic Panel, except in the case of download that presets minimum/maximum or basic value of the parameter by input type in PC loader program. © Copyright Reserved Autonics Co., Ltd.
Page 13: Exception Response-Error Code
03 H E8 H 00 H 01 H ## H ## H Response (Slave Side) Error Check(CRC16) Slave Address Function(Command)+80 H Exception Code High 11 H 81 H 02 H ## H ## H © Copyright Reserved Autonics Co., Ltd.
Page 14
1 Modbus RTU Protocol © Copyright Reserved Autonics Co., Ltd.
Page 15: Modbus Mapping Table
1: ON 100011(000A) MAN Indicator Manual Control Indicator 0: OFF 1: ON 100012(000B) DI-1 input DI-1 Input Status 0: OFF 1: ON 100013(000C) DI-2 input DI-2 Input Status 0: OFF 1: ON 100014(000D) Reserved 100015~100050 © Copyright Reserved Autonics Co., Ltd.
Page 16: Read Input Registers(Func04)
Holding Register Quantity - 300123(007A) Input Register Start 0000 300124(007B) Address Input Register Quantity 300125(007C) Reserved 300127~300200 ℃/℉/- Present Value -1999 ~ 9999 301001(03E8) 0: 0 1: )0 Decimal point location 301002(03E9) 2: )00 3: )000 © Copyright Reserved Autonics Co., Ltd.
Page 17
OUT1 Ind. % Ind. ℉ Ind. ℃ Ind. 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 1 Byte © Copyright Reserved Autonics Co., Ltd.
Page 18: Read Holding Register(Func03) / Write Single Register(Func06) / Write Multiple Registers(Func16)
SV-1 Set Value Range from L-SV~H- SV 400059(003A) SV-1 ℃/℉/- 0000 SV-2 Set Value Range from L-SV~H- SV SV-2 0000 400060(003B) ℃/℉/- SV-3 Set Value Range from L-SV~H-SV SV-3 0000 400061(003C) ℃/℉/- Reserved 400062~400100 © Copyright Reserved Autonics Co., Ltd.
Page 19: Parameter 2 Setting Group [Func: 03/06/16, Rw: R/W]
Ramp Up-Change Rate Digit RAMU 0~9999: 00)0~99(9(Temperature L) 0~999: 000~999(Temperature H, Analog) Ramp Down-Change 400117(0074) Digit RAMD 0000 Rate 0~9999: 00)0~99(9(Temperature L) 400118(0075) Ramp Time Unit 0: SEC 1: MIN 2: HOUR rUNT 400119~400150 Reserved © Copyright Reserved Autonics Co., Ltd.
Page 20: Parameter 3 Setting Group [Func: 03/06/16, Rw: R/W]
0: SSR 1: CURR OUT2 Type OUT2 Current Output 400170(00A9) 0: 4-20 1: 0-20 O@MA 4-20 Range 400171(00AA) Heating Control Time 1~1200: 00)1~2)0 Sec. 02)0 400172(00AB) Cooling Control Time 1~1200: 00)1~12)0 Sec. 02)0 400173~400200 Reserved © Copyright Reserved Autonics Co., Ltd.
Page 21: Parameter 4 Setting Group [Func: 03/06/16, Rw: R/W]
Parity Bit 0: NONE 1: EVEN 2: ODD PRTY NONE 400222(00DD) Stop Bit 0: 1 1: 2 400223(00DE) Response Waiting Time 5~99: 5~99 RSW.T 400224(00DF) Communication Write 0: EnA 1: DIsA COMW 400225~400250 Reserved © Copyright Reserved Autonics Co., Ltd.
Page 22: Parameter 5 Setting Group [Func: 03/06/16, Rw: R/W]
Parameter 4 Group 400266(0109) 0: OFF 1: ON LcP4 Lock Parameter 5 Group 400267(010A) 0: OFF 1: ON LcP5 Lock 0000: OFF 0002~9999: Password Setting Range 400268(010B) Password Setting 0000 (※0001:read-only password) 400269~400300 Reserved © Copyright Reserved Autonics Co., Ltd.
Page 24
-TKC1-V01.4-1202US...
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the TK Series and is the answer not in the manual?
Questions and answers