Heating Specifications - Intertek 25-CAB80 Manual

Table of Contents

Advertisement

Heating Specifications

• Approximate Pellet Burn Rate**......................1.0 to 1.8 kg/hr (2.2 to 3.8 lbs/hr)
• Maximum Burn Time**...................................................................................36 hours
• Approximate Square Footage Heated***...........................................up 2,000 sq. ft.
• Hopper Capacity (fuel)..................................................................................80 pounds
Dimensions
EPA and Safety Compliance Specifications
• EPA Compliance Status ...................... Certified to comply with 2020 particulate emission standards
using pellet fuel.
• U.S. Test Standard: US EPA 40 CFR Part 60, Subpart 60.536
• Heat output range****................ 11,641 BTU/h to 20,959 BTU/h (3.41kW to 6.14 kW)
• Particulate Emissions ........................................................................... 1.130 grams/hr
• CO Emissions ........................................................................................ 0.029 grams/hr
• Efficiency................................................................................................... 64.1 % (HHV)
• BTU rating ................................................................................................. 20,511 BTU/hr
• Tested To ASTM E 1509, ASTM E2779, ASTM E2515, CSA B415.1 & ULC S627
Notes for this unit: Product may vary slightly from diagram. Clearances are the minimum for this unit
and may need to be increased in the rear to have proper vent clearances. Follow all venting manufacturer
clearances and local codes.
*- As tested per ASTM 2779
** - Heat output, burn rate and maximum burn time are heavily dependent on the type of pellets burned in the stove; as such, these numbers may vary.
*** - The maximum heating capacity of this unit can vary greatly based on climate, construction style, insulation and a myriad of other factors. Use this information
in conjunction with a BTU loss calculation for your home to determine if this unit will be sufficient for your needs.
**** - As measured per CSA B415.1-10 stack loss method.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR
SPECIFICATIONS
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

55-shpcab8055-trcab80

Table of Contents