Greenheck DOAS v8.1 Reference Manual page 45

Microprocessor controller
Table of Contents

Advertisement

Variable
Device_Enable_DO_Word
Ref_Ckt_PressTemp_Alarm_Word Refrigeration Circuit Word - See Table
Device_Offline_Word
Device_Alarm_Word
System_Word
Unit_Status_Word
Exhaust_Fan_1_Status_Digital_
Input
Supply_Fan_1_Status_Digital_
Input
BMS_Watchdog
System_Enable
BMS_Occupancy_Command
Reset_All_Alarms
Exhaust_Only_Mode_BMS_Cmd
Pressurization_Only_Mode_BMS_
Cmd
Outside_RH_Source_BMS
Outside_Temp_Source_BMS
Return_RH_Source_BMS
Return_Temp_Source_BMS
Space_1_CO2_Source_BMS
Space_2_CO2_Source_BMS
Return_CO2_Source_BMS
Space_RH_Source_BMS
Space_Static_Source_BMS
Space_Temp_Source_BMS
SF_Control_Source_BMS
EF_Control_Source_BMS
OAD_Control_Source_BMS
Aux_BMS_Digital_Output_1
Aux_BMS_Digital_Output_2
Occupied
Appendix E: Points List
Description
Device Enable DO Word - See Table
Device Offline Word - See Table
Device Alarm Word - See Table
System Word - See Table
Unit Status Word - See Table
Exhaust Fan Status
Supply Fan Status
"BMS Watchdog command
Used to determine BMS comm status
Must heartbeat within the watch dog
timeout delay to detect comm status"
Master system enable/disable point
Occupancy Command
Alarm Reset Command
Exhaust Mode Command
Pressurization Mode Command
Outside RH Source Selection
Outside Temp Source Selection
Return RH Source Selection
Return Temp Source Selection
Space 1 CO2 Source Selection
Space 2 CO2 Source Selection
Return CO2 Source Selection
Space RH Source Selection
Space Static Source Selection
Space Temp Source Selection
Allows the BMS to control supply fan speed
Allows the BMS to control exhaust fan
speed
Allows the BMS to control OAD position
BMS Commanded auxiliary digital output
BMS Commanded auxiliary digital output
Occupancy
BACnet Modbus
Read
or
Object
Register
Write
IV-6
30206
R
IV-7
30210
R
IV-8
30214
R
IV-9
30218
R
IV-10*
30222
R
IV-11*
30226
R
BI-1*
10009
R
BI-2*
10010
R
BV-1*
2
RW
BV-2*
3
RW
BV-3*
4
RW
BV-4*
5
RW
BV-5
6
RW
BV-6
7
RW
BV-7
8
RW
BV-8
9
RW
BV-9
10
RW
BV-10
11
RW
BV-11
12
RW
BV-12
13
RW
BV-13
14
RW
BV-14
15
RW
BV-15
16
RW
BV-16
17
RW
BV-17
18
RW
BV-18
19
RW
BV-19
20
RW
BV-20*
21
RW
BV-21
22
RW
BV-22*
10002
R
Microprocessor Controller for DOAS
Text or Unit of M
Active Inactive
Bit Packed Word
Bit Packed Word
Bit Packed Word
Bit Packed Word
Bit Packed Word
Bit Packed Word
Active
Inactive
Active
Inactive
Active
Inactive
Enable
Disable
Unoccupied
Occupied
Reset
Normal
Enable
Disable
Enable
Disable
BMS
Local
BMS
Local
BMS
Local
BMS
Local
BMS
Local
BMS
Local
BMS
Local
BMS
Local
BMS
Local
BMS
Local
BMS
Local
BMS
Local
BMS
Local
Active
Inactive
Active
Inactive
Occupied
Unoccupied