Page 29
6.35mm x 1.57m,刚性 x 旋转,家禽 燃气软管 550-20495* 6.35mm x 1.83m,刚性 x 旋转,家禽 550-20496* 6.35mm x 3.05m,刚性 x 旋转,家禽 550-20497* 6.35mm x 3.65m,刚性 x 旋转,家禽 550-20499* 6.35mm x 1.83m,旋转两端,猪 550-20242* 6.35mm x 3.05m,旋转两端,猪 550-20500* 6.35mm x 4.57m,旋转两端,猪 500-23406* 套件,1/8 美标锥度螺纹配件 用户手册 • I-17...
Page 31
We, at L.B. White, thank youfor your confidence in our products and welcome any suggestions or comments you may have...call us toll free at 1-800-345-7200. SCAN THIS...
Page 32
Installing Dust Filter (Accessory) ...................... 12 Start-Up Instructions ......................... 13 Shut-Down Instructions ........................13 Cleaning Instructions ........................14 Maintenance Instructions ........................15 General Service Instructions ......................16 Troubleshooting Guide ........................22 Parts Identification and Parts List ..................... 27 Warranty Policy..........................30 Owner’s Manual • I-17...
Page 33
■ SAVE THIS OWNER’S MANUAL FOR FUTURE USE AND REFERENCE. ■ OWNER’S MANUALS AND REPLACEMENT LABELS ARE AVAILABLE AT NO CHARGE. SEE WEBSITE, OR FOR ASSISTANCE, CONTACT L.B. WHITE AT 1-800-345-7200. WARNING ■ PROPER GAS SUPPLY PRESSURE MUST BE PROVIDED TO THE INLET OF THE BROOD HEATER.
(1) There are other factors that will affect the quantity of animals each brood heater can cover. These include building ventilation and control systems, building insulation, building size and population density, etc. Consult your L.B. White dealer or call L.B. White for specific recommendations for your application.
See page 7 for definition of the necessary qualifications. Contact your local L.B. White distributor or the L.B. White Company, LLC for assistance, or if you have any questions about the use of the equipment or its application.
Page 36
■ Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously. Owner’s Manual • I-17...
Page 37
This must be done in accordance with all by the manufacturer. See parts list. local, state and national codes as well as the manufacturer’s requirements. Owner’s Manual • I-17...
-- Leak check of all pipe joints and hose connections. 8. Check all connections for gas leaks using approved gas leak detectors. Gas leak testing is -- Thorough cleaning of the exterior of the brood performed as follows: heater, its burner assembly, and emitter. Owner’s Manual • I-17...
Page 39
-- Ensure all gas leaks have been identified and repaired before proceeding. 9. A qualified service agency must check for proper operating gas pressures upon installation of the brood heaters. Owner’s Manual • I-17...
Page 40
TO 5 DEGREES DOWN FROM POINT OF COMBUSTION HORIZONTAL (SEE BELOW) CONE TO FLOOR THIS NOT THIS STEEL CABLE OR CHAIN HANGING BRACKET QUICK LINK CONTROL END OF HEATER CONTROL END MUST BE 1” TO 5° DOWN FROM HORIZONTAL Owner’s Manual • I-17...
CONNECT HOSE TO GAS INLET INTO COUPLING & TIGHTEN SECURELY NIPPLE - RELEASE COLLAR. ENSURE MALE HOSE END IS SECURELY DUST CAP LOCKED INTO COUPLING. - ASSEMBLE COUPLING KIT, PART #21335, & TIGHTEN COMPONENTS SECURELY. - CONNECT TO GAS SUPPLY. Owner’s Manual • I-17...
34.5 kPa nominal. Consult your local L. B. White dealer or distributor or call the L. B. White Co. for recommendations on the best configuration of zone panels for your specific application. Owner’s Manual • I-17...
Remove the vinyl cap from the safety valve if necessary. See Fig.8, I-17 shown. Keep the button fully depressed for about 30 seconds until the inner cone stays lit. Release the button. Allow outer combustion cone to heat up completely.
Fig. 11, on next page. 5. Inspect the cones and venturi tube to make sure these areas are clean. 6. Return the brood heater to its normal hanging position and relight the brood heater. Owner’s Manual • I-17...
- Use compressed air or water (standard faucet damaged labels must be replaced immediately pressure) to clean it. by contacting the L.B. White Co., LLC. - Do not use high pressure water, air, or a washing machine. Filter material damage may occur.
Doing so will enlarge the on the dataplate, then the regulator controlling gas hole, causing combustion or ignition problems. Replace pressure to the brood heater requires adjustment. the orifice if it cannot be cleaned properly. Owner’s Manual • I-17...
Page 47
I-17 Brood Heater D. Completion SAFETY GAS CONTROL VALVE I-17 (Fig. 13) 1. Once gas pressure has been confirmed and/or properly set, close the fuel supply valve to the 1. Disconnect the gas hose. brood heater and allow the brood heater to burn off any gas remaining in the gas supply hose.
Page 48
FIG. 16 Thermostatic Head ADAPTER FIG. 15 VALVE BODY HOSE ADAPTER ADAPTER Attachment Knob FLATS Valve Pin THERMOSTATIC HEAD FIG. 17 LOW FIRE ORIFICE Modulating Valve THERMOSTATIC HEAD Owner’s Manual • I-17...
Page 49
2. Pull the air housing from the venturi tube to allow access to orifices. OUTER CONE REMOVAL I-17 a. Using pliers,straighten the tab on the truss clip. 3. Using a 6 mm hex nut driver, remove the orifice. Clean or See Fig.
Page 50
A bottle before final installation. brush may also be run down the venturi tube to -- Model I-17: Outer cone flange is positioned under all force out any blockages. Using air at the cone end, retainers.
Page 51
-- A reading of less than 1 ohm is acceptable. A reading Air Housing showing overload or infinite resistance indicates an Venturi Tube open circuit. -- If open or the reading is not 1 ohm or less, replace the thermocouple. Auto Reset Temperature Switch Thermocouple Nut Owner’s Manual • I-17...
■ Troubleshooting this system may require operating the brood heater with the burner on. Use extreme caution when working on the brood heater. ■ Failure to follow this warning will result in burns causing severe injury. Owner’s Manual • I-17...
I-17 Brood Heater Service Parts Identification Schematic I-17 Owner’s Manual • I-17...
Page 58
572121 Adapter, hose, individual control 572940 Thermostatic head, individual control with 1.83m lead and sensor 509415 Valve, modulating, individual control Propane gas 500-09750 Natural gas 570411 Orifice, bypass, individual control Propane gas 572140 Natural gas 570326 Owner’s Manual • I-17...
Page 59
6.35mm x 3.05 m, Swivel Both Ends, Swine 550-20242* 6.35mm x 4.57 m, Swivel Both Ends, Swine 550-20500* Kit, 1/8 NPT Fitting 500-23406* *Accessory - Must be ordered separately Manual Rev./Changes Date Rev. Revision Change Description 1/19/2023 New model released, Individual Control, China Owner’s Manual • I-17...
Contact your local L.B. White dealer for replacement parts the date of purchase by the end user. Warranty is and service. You may also call the L.B. White Company, automatic if a component is found defective within 12 LLC at 1-800-345-7200, for assistance, or email us at months of the date code marked on the part.
Need help?
Do you have a question about the I-17 and is the answer not in the manual?
Questions and answers