Service Procedures

Reference Material

Changing the Voltage

25A1041 (RA)
Shure AMS8100 Automatic Microphone Mixer
Refer to the Service Equipment Manual for standard test equipment.
The AMS8100 can be internally modified to operate from either
120 Vac or 230 Vac power. Follow these steps to change the
operating voltage:
1. Disconnect the unit from the ac power source.
2. Remove the eight Phillips head screws to remove the top cover.
3. Locate voltage selector switch SW903 adjacent to the power
transformer (T901).
4. Use a screwdriver to turn the center rotor to the 230 V position
for 230 V operation, or to the 120 V position for 120 V operation.
5. Locate fuse F901 and remove it.
6. Replace fuse F901 with a 100 mA, 250 V, time-delay fuse for
230 V operation, or a 200 mA, 250 V, slow-blow fuse for 120 V
operation.
7. If changing to 230 V operation, replace the power cord with a
cord rated for 230 V operation (an IEC appliance connector on
the equipment end and a CEE 7/7 Schuko mains connector on
the other end).*
8. If changing to 120 V operation, replace the power cord with a
cord rated for 120 V operation (an IEC appliance connector on
the equipment end and a mains connector suitable for 120 V
operation on the other end).*
*For systems that require other mains connectors, obtain a power
cord with an IEC 320 type mating connector for connection to the
unit, and an appropriate plug on the other end for connection to the
mains.