GENERAL
The FP42 is a 4-input, 2-output, compact, self-contained stereo
mixer for applications in broadcasting, recording and sound rein-
forcement. The high-reliability FP42 integrates all the operating
features of a professional stereo mixer in a single unit—small and
lightweight enough for location use, but with the reliability of a stu-
dio console.
FEATURES
S
Wide, flat frequency response, low distortion, and high
output level
Reliable operation under all temperature and humidity
S
conditions
Protected against RF interference and damage from input
S
overload and shorted outputs
Four transformer-coupled XLR inputs, each microphone-line
S
switchable with low-cut filters and cuing function
S
Full-separation pan pots with center detent on each input for
precise spatial positioning
S
Phantom power for condenser microphone operation
S
Built-in tone oscillator permits level checking and line testing
S
Left- and right-channel transformer-coupled XLR outputs,
with microphone-line and mono-stereo switches
S
Parallel stereo headphone jacks (1/4-inch and mini) with
level control
Left and right mix bus jacks
S
Active, feedback-type input gain controls for high-level input
S
signals without input attenuators
Adjustable-threshold limiter with left- and right-channel peak
S
indicators
VU meters with range switch and battery check function
S
Left- and right-channel master level controls and ganged
S
headphone level control
S
Powered by ac (120 or 240V—internally selectable) or
built-in battery pack
S
Low battery drain provides up to 10 hours operation under
normal conditions
Noiseless and automatic switchover to and from battery
S
power
Rugged, durable construction
S
Compact and lightweight for field use and transporting
S
Rack-mountable with accessory rack mount kit
S
Listed by Underwriters Laboratories, Inc.;
S
listed by Canadian Standards Association as Certified
ã2004, S hure I nc orporat ed
27A 8795 (Rev. 1)
Model FP42 User Guide
Stereo Microphone Mixer

CONTROLS AND CONNECTIONS

Power Off/On Switch: applies power to the FP42 circuitry.
Channel Level/Cue Rotary Controls: adjust individual input
channel signal levels. Each channel can be cued by pulling the con-
trol knob outward, rotating the knob to the desired level, and push-
ing the knob inward to activate the channel.
Lo Cut Filter Slide Switches: reduce unwanted low-frequency
signals such as wind noise by 6 dB per octave at 150 Hz.
Pan L- -R Rotary Controls: assign each input channel signal to the
left (L) or right (R) output channel, or equally to each output channel
(center detent).
Master Rotary Control: determines mixed output level at left (L)
and right (R) output connectors. The control is "clutched": both
channel levels can be set simultaneously, or the left (inner knob) or
right (outer knob) channel can be set individually. The control also
sets the tone oscillator level when the Tone Osc switch is turned on.
Mono/Stereo Slide Switch: selects either monophonic output sig-
nals (both left and right output connectors carry the same signal) or
stereo operation (input channel signals are assigned to left or right
output channels depending on Pan control positions).
Limiter In/Out Slide Switch: activates fast-acting, peak-respond-
ing limiter circuit to cut overload distortion during loud program in-
tervals without affecting normal program levels.
Peak/Limiter LEDS: indicate limiter operation with the limiter in,
and indicate approaching program overload with the limiter out.
The LEDs are activated by the shortest transient peak, but remain
on long enough to provide easy recognition.
L and R VU Meters: indicate 0 VU with a +4 dBm output (recom-
mended for normal use to provide approximately 14 dB headroom
from operating level to clipping level). Rear-panel VU Range +4/+8
slide switch permits changing to 0 VU = +8 dBm. The VU meters are
lit during ac operation only; therefore, the illumination serves as a
visual alarm if the ac is interrupted and the unit has automatically
switched to battery operation.
Batt Check Momentary Push-button Switch: operates in con-
junction with the left-channel VU meter to indicate battery condi-
tion. With the Power switch on and the switch depressed, a new set
of batteries will give about a +2 VU indication. Battery condition is
good if the reading is above 0 VU: a lower reading means that new
batteries are required for proper operation.
Tone Osc Off/On Slide Switch: provides a highly stable, low-dis-
tortion 1-kilohertz tone for line tests and level checks. The tone sig-
nal level is controlled by the Master Level control. The tone signal
appears on both the line and microphone outputs, as well as the
Headphones and Mix Bus connectors. The tone oscillator should
be switched off when not in use.
Headphones 1/4-inch Stereo Phone Jack and Miniature 3.5
mm Stereo Phone Jack: permit monitoring mixer output through
most stereo headphones. The Headphones rotary control adjusts
Printed in U.S.A.

Advertisement

Table of Contents
loading

Summary of Contents for Shure FP42

  • Page 1: Controls And Connections

    GENERAL The FP42 is a 4-input, 2-output, compact, self-contained stereo mixer for applications in broadcasting, recording and sound rein- forcement. The high-reliability FP42 integrates all the operating features of a professional stereo mixer in a single unit—small and lightweight enough for location use, but with the reliability of a stu- dio console.
  • Page 2: Installation And Operation

    INSTALLATION AND OPERATION Battery Operation In addition to 120- or 240-volt ac operation, the FP42 can be oper- ated from an internal battery pack. Current drain is typically 32 mA at + 4 dBm output level. Battery operation is recommended for re- mote, on-location operation, and as an emergency backup source in case of ac power failure.
  • Page 3: Specifications

    When using the FP42 connected directly to a telephone line, check to see whether the telephone company requires an interface cou- pler between the FP42 and the telephone line. If a coupler is re- quired, make certain the coupler selected and the wiring arrange- ment are in compliance with local telephone company regulations.
  • Page 4 (It is not necessary to remove the end caps from the cover for access to the chassis.) 240 Vac Operation To change the FP42 operating voltage from 120 Vac to 240 Vac, fol- low these steps. Locate the Power board.
  • Page 5: Commandes Et Raccordements

    GÉNÉRALITÉS Le modèle FP42 est un mixeur stéréo à 4 entrées et 2 sorties. Com- pact et autonome, il est parfait pour une utilisation en radiodiffusion, enregistrement et renforcement du son. Outre sa grande fiabilité, le modèle FP42 réunit toutes les caractéristiques de fonctionnement d’un mixeur stéréo professionnel en un seul appareil.
  • Page 6: Installation Et Fonctionnement

    0 VU ; un nombre plus faible signifie que de nouvelles piles sont nécessaires pour un fonctionnement correct. (Il est à noter qu’il est nécessaire de mettre le modèle FP42 en mar- che pour vérifier l’état de charge des piles.) Raccordements Raccorder les signaux sources aux prises d’entrée XLR à...
  • Page 7: Caractéristiques Techniques

    Interconnexion avec le téléphone Lorsque le modèle FP42 est directement connecté à une ligne télé- phonique, vérifier si la compagnie de téléphone exige ou non l’utilisa- tion d’un coupleur d’interface entre le FP42 et la ligne téléphonique.
  • Page 8: Entretien

    Confier toute réparation à du personnel qualifié. Démontage Le modèle FP42 peut être démonté comme suit. Retirer les quatre vis fixant le couvercle sur le châssis. Soulever le couvercle avec précau- tion et le retirer du châssis, en prenant soin de ne pas accrocher les fils ni les composants.
  • Page 9: Allgemeine Beschreibung

    ALLGEMEINE BESCHREIBUNG Der FP42 ist ein kompakter, autonomer Stereo–Mischer mit 4 Ein- gängen und 2 Ausgängen für den Einsatz bei Sendungen, Aufnah- men und Audioverstärkungen. Der leistungsfähige FP42 vereint die Merkmale eines professionellen Stereo–Mischers in einer einzigen Einheit — kompakt und leicht genug für den Transport bei Außenauf- nahmen —...
  • Page 10 0–VU liegt. Liegt die Anzeige unter diesem Wert, so sollten neue Bat- terien eingelegt werden, um einen einwandfreien Betrieb zu gewähr- leisten. (Es ist zu beachten, dass der FP42 eingeschaltet sein muss, um den Betriebszustand der Batterien zu prüfen.) Steckverbindungen Die Signalquellen an die 3–poligen XLR–Eingangsbuchsen an-...
  • Page 11: Technische Daten

    Telefonleitungen an der primären Seite des Ausgangstransfor- mators angeschlossen. Telefonanschluss Soll der FP42 direkt an eine Telefonleitung angeschlossen werden, so muss zunächst festgestellt werden, ob das Telefonsystem einen Interface–Koppler zwischen dem FF42 und der Telefonleitung erfor- dert. Wird ein Koppler benötigt, ist sicherzustellen, dass der fragliche Koppler und die Verkabelung den Richtlinien der örtlichen Telefon-...
  • Page 12: Wartung

    Standards Association per Zertifizierung. ZUBEHÖR Der Rackeinbausatz Modell A16R besteht aus einem vorgeschnitte- nen, 483 x 89 mm großen Rackfeld und den zum Einbau eines FP42 in ein Rackfeld der Standardgröße 483 mm (19 Zoll) erforderlichen Befestigungsteilen, wobei die Endplatten abgenommen werden, aber die Abdeckung installiert bleibt.
  • Page 13: Controles Y Conexiones

    La FP42 es una mezcladora estereofónica autocontenida compacta con 4 canales de entrada y 2 de salida para uso en situaciones de difusión, grabación y refuerzo de sonido. La FP42 de alta confiabili- dad integra todas las características funcionales de una consola mezcladora de calidad profesional en una sola unidad—pequeña y...
  • Page 14 Conecte el cable de alimentación a una fuente de 120 VCA +10%, 50/60 Hz, si la FP42 va a alimentarse con CA. Si se va a usar la uni- dad con 240 VCA, consulte la sección Servicio. Ajustes Coloque el interruptor de alimentación en la posición conectada (los...
  • Page 15: Especificaciones

    Cuando se conecta la FP42 directamente a una línea telefónica, veri- fique si la compañía telefónica exige la instalación de un acoplador de interfaz entre la FP42 y la línea telefónica. Si se requiere un aco- plador, asegúrese que el acoplador seleccionado y el alambrado sa- tisfagan los reglamentos de la compañía telefónica.
  • Page 16 F202. Reemplace el cable eléctrico (de ser necesario) por uno dise- ñado para la fuente de 240 V. Si la FP42 va a usarse fuera de los EE.UU. y Canadá, los reglamentos locales pueden exigir que se reemplace el cable eléctrico por uno cuyos aislantes tengan los colores siguientes: ”Vivo”...
  • Page 17 MODEL FP42 CIRCUIT DIAGRAM...
  • Page 18 PRINTED CIRCUIT BOARD PRINTED CIRCUIT BOARD Component Side Solder Side...
  • Page 20 SHURE Incorporated Web Address: http://www.shure.com 5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A. In U.S.A., Phone: 1-847-600-2000 Fax: 1-847-600-1212 In Europe, Phone: 49-7131-72140 Fax: 49-7131-721414 In Asia, Phone: 1-852-2893-4290 Fax: 1-852-2893-4055 International Fax: 1-847-600-6446...

Table of Contents