Unpack the GGA-1 and keep packaging materials to store the GGA-1 after test fi tting.
1.
Ensure to handle the GGA-1 as shown (Fig. 1) as the fl oating intermediate glass might fall out of the assembly if
2.
handled incorrectly.
For ease of installation during preliminary adjustment, remove the door trim, control cover and access panel
3.
(Fig. 3).
For ease of fi tting, the latch securing screws should be located at the bottom of their slots. it may be necessary
4.
to loosen the latch securing screws and slide them all the way down. Retighten the latch securing screws
loosely taking care not to overtighten (Fig. 4). Repeat for other end of GGA-1.
Latch
Latch securing
screws
(DO NOT REMOVE)
Latch bracket
mounting screws
(FOR ADJUSTMENT)
Latch mounting
bracket
(FOR ADJUSTMENT)
Door rail support
(FIXED)
note:
DO NOT OVERTIGHTEN.
fi nishing
Access panel
Control cover
Door trim
GGA
Fig. 3
Door rail support
mounting screws
(DO NOT LOOSEN)
Fig. 4