WARNING
!
Do NOT cover or place any items in the Dynamic Heat Control™ air outlet. Failure to comply with these
instructions will create a fi re hazard.
Ensure air fl ow within the air passage is not restricted in any way with the exception of approved venting.
Read Dynamic Heat Control™ section before proceeding.
No materials of any type
are permitted in this area
Control™ air
outlet opening
Combustible
studding MUST
not be used past
the dotted line
Header
Standoff
Upper
Frame
Air fl ow in the shaded area must not be restricted in any way with the exception of an approved appliance vent
system. No other items are allowed in this area.
Shaded framing must use non-combustible materials.No combustible materials allowed in this area or the space
between studs (i.e. no wiring, conduits, electrical bores, combustible framing members, AV equipment, fi nishing
brackets, framing, etc.)
Dynamic
Dynamic
Heat
Heat
Control™
air outlet
opening
3"
Single-Sided
*Restrictions also apply to see-thru when one or more recess is used.
installation planning
4.0 installation planning
enclosure top
and/or ceiling
Dynamic
Heat
Control™
air outlet
opening
Single-Sided
(Recessed)*
EN
Dynamic
Heat
Control™ air
outlet opening
See-thru