2. DESCRIPTION

Cab Operating Panel (COP) Buttons
(Figure 1-A)
The Cab Operating Panel (COP) buttons facilitate
the UP/DOWN movement of the cab between
landings. Once the selected landing button is
pressed, the cab will automatically move to the
landing. The cab will stop when the selected
landing is reached.
Door Open/Close Buttons (Figure 1-B)
The elevator door will close automatically after a
preset adjustable time in seconds. These buttons
can be pressed to open/close the door when the
cab is at a landing.
Alarm Button (Figure 1-C)
This button can be pressed at any time to sound
the alarm in case of an emergency.
Run/Stop Keyswitch (Figure 1-D)
In the STOP position, the cab stops and the alarm
buzzer is activated. This key switch must be in the
RUN position for normal operation.
Phase 2 Fire Service Keyswitch - Optional
(Figure 1-E)
The keyswitch in the ON position enables cab
controls as per Code B44 2.27. The keyswitch in
the OFF position allows for normal lift operation.
The keyswitch in the HOLD position holds the
doors open when the cab is at a landing.
Call Cancel Button (Optional)
Used with Fire Service 2; when pressed, this
button cancels all registered calls. The cab will
stop at the next landing.
Help (Phone) Button - Optional (Figure 1-F)
This button can be pressed at any time to activate the optional hands-free
phone in case of an emergency. The red light above the speaker will come on
when two-way communication has been established. For units that have a
standard hand-held phone, it is located in a separate phone cabinet in the cab.