IntesisBox
®
KNX – FUJITSU VRF
Control_Fan speed med
Status_Fan speed med
Control_Fan speed med-high
Status_Fan speed med-high
Control_Fan speed high
Status_Fan speed high
Control_Fan speed quiet
Status_Fan speed quiet
Control_Fan speed Man/Auto
INDOOR UNIT
Status_Fan speed Man/Auto
SIGNALS
Control_Vanes UD enumerated
Status_Vanes UD enumerated
Control_Vanes UD scaling
Status_Vanes UD scaling
Control_ Vanes UD pos-1
Status_ Vanes UD pos-1
Control_ Vanes UD pos-2
Status_ Vanes UD pos-2
Control_ Vanes UD pos-3
VANE POS
Status_ Vanes UD pos-3
Control_ Vanes UD pos-4
Status_ Vanes UD pos-4
Control_ Vanes UD swing
Status_ Vanes UD swing
Control_Vanes LR enumerated
Status_Vanes LR enumerated
Control_Vanes LR scaling
This information is subject to change without prior notice
IntesisBox is a registered trademark of Intesis Software S.L.U.
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 byte
Non-standarized
1 byte
Non-standarized
1 byte
DPT_Scaling
1 byte
DPT_Scaling
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 bit
DPT_Switch
1 byte
Non-standarized
1 byte
Non-standarized
1 byte
DPT_Scaling
1.001
W
1-Set fan speed med
1.001
R
T
1-Speed med active, 0-Speed med not active
1.001
W
1-Set fan speed med-high
1.001
R
T
1-Speed med-high active, 0-Speed med-high not active
1.001
W
1-Set fan speed high
1.001
R
T
1-Speed high active, 0-Speed high not active
1.001
W
1-Set fan speed quiet
1.001
R
T
1-Speed quiet active, 0-Speed quiet not active
1.001
W
0-Manual; 1-Auto
1.001
R
T
0-Manual; 1-Auto
5.x
W
1-Position 1..4-Position 4
5.x
R
T
1-Position 1..4-Position 4
Thersholds (0%..37%; 38%..62%; 63%..87%;
5.001
W
88%..100%)
5.001
R
T
Thersholds (25%; 50%; 75%; 100%)
1.001
R
T
1-Set position-1 vanes
1.001
W
1-Vane position-1 active, 0-Vane position-1 not active
1.001
R
T
1-Set position-2 vanes
1.001
W
1-Vane position-2 active, 0-Vane position-2 not active
1.001
R
T
1-Set position-3 vanes
1.001
W
1-Vane position-3 active, 0-Vane position-3 not active
1.001
R
T
1-Set position-4 vanes
1.001
W
1-Vane position-4 active, 0-Vane position-4 not active
1.001
R
T
0-Swing off; 1-Swing on
1.001
W
0-Swing off; 1-Swing on
5.x
W
1-Position 1..5-Position 5
5.x
R
T
1-Position 1..5-Position 5
Thersholds (0%..29%; 30%..49%; 50%..69%;
5.001
W
70%..89%; 90%..100%)
email:
info@intesisbox.com
web:
www.intesisbox.com
phone: +34 938047134
User Manual r1.0 EN
28/30