7. COMMAND DESCRIPTION
(25) NOP
Non-OPeration
E R/W
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
0
1
0
1
(26) Test
IC chip test command. Do not use this command. If the test command is used incorrectly, it can be reset by setting the
RES input to LOW or by using the reset command or NOP.
E R/W
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
0
1
0
1
(Note) Although the S1D15710 series holds the command operating state, it may change the internal state if excessive
foreign noise is entered. Such action that suppresses the generation of noise and prevents the effect of noise
needs to be taken on installation and systems. Besides, to prevent sudden noise, it is recommended that the
operating state should periodically be refreshed.
38
1
1
0
0
0
1
1
1
*
*
1
1
*
*
*: Invalid bit