Table of Contents Drawing No. LP1182 Revision A NT5018-DM2 Dimensions In inches [mm] NT5018-FX2 Specifications NT5018-FX2 Dimensions In inches [mm]...
Page 5
While every effort has been made to ensure that this document is complete and accurate at the time of release, the information that it contains is subject to change. Red Lion Controls, Inc. is not responsible for any additions to or alterations of the original document.
Page 6
CAUTION: Risk of Danger Read complete instructions prior to installation and operation of the unit. CAUTION: If equipment is used in a manner not specified by Red Lion, the protection provided by the equipment may be impaired. CAUTION: Do not perform any services on the unit unless qualified to do so. Do not substitute unauthorized parts or make unauthorized modifications to the unit.
Page 7
ATTENTION: Risque de danger Lire les instructions complètes avant l’installation et l’utilisation de l’appareil. ATTENTION: Si équipement est utilisé d’une manière non spécifiée par Red Lion, la protection fournie par l’équipement peut être compromise. ATTENTION: Ne pas effectuer de services sur l’appareil s’il n’est pas qualifié pour le faire. Ne pas substituer pièces non autorisées ou de modifications non autorisées de l’appareil.
Page 8
Preface Drawing No. LP1182 Regulatory Information Revision A Regulatory Information Product Safety UL 61010 and C22.2 No. 61010 Ordinary Locations UL 121201 and CSA C22.2 No. 213 Class I, Division 2 Hazardous Locations ATEX, IECEx and UKEx II 3 G Ex ec nC IIC T4 Gc UL 20 ATEX 2645X UL 22.0038X IECEx...
Page 9
The latest online version of this document can be accessed through the Red Lion website at www.redlion.net/support/documentation. Additional Product Information Additional product information can be obtained by contacting the local sales representative or Red Lion through the contact numbers and/or support website address listed on the inside of the front cover. NT5000 Gigabit Managed...
Page 11
Drawing No. LP1182 Chapter 1 Introduction Revision A Chapter 1 Introduction The NT5000 Gigabit Industrial Ethernet Managed switches offer compact, hardened solutions for reliable operation in harsh industrial applications. Designed for quick installation and ease of use, the NT5000 switches provide a modern graphical user interface with a quick start wizard to assist administrators through configuration for fast and easy deployment.
Page 12
Chapter 1 Introduction Drawing No. LP1182 Features and Benefits Revision A Features and Benefits • Password encryption DIAGNOSTIC FEATURES HARDWARE FEATURES • Port mirroring • Compact, space saving, hardened industrial design • Event log/Syslog • Wide operating temperature • LLDP • High shock and vibration tolerance • Advanced cable diagnostics Shock: IEC 68-2-27: 200 g @ 10 ms Triaxial;...
Page 13
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5006 Specifications NT5006 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.5M Hours IP20 3.85" (97.8 1.65" (41.9 mm) 5.11" (129.8 mm) 1.09 lbs. (0.50 kg) DIN rail or optional panel mount POWER Input...
Page 14
Chapter 1 Introduction Drawing No. LP1182 NT5006 DIMENSIONS In inches [mm] Revision A NT5006 DIMENSIONS In inches [mm] DIN rail 4.83 [122.6] 1.65 [41.9] 0.38 [9.7] 0.39 [10] 3.85 4.19 5.11 [106.3] [97.8] [129.8] 0.2 [5.5] Optional panel mount 0.53 5.11 [129.8] [13.4] 1.65...
Page 15
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5006-DM2 Specifications NT5006-DM2 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.5M Hours IP20 3.85" (97.8 1.65" (41.9 mm) 5.11" (129.8 mm) 1.13 lbs. (0.51 kg) DIN rail or optional panel mount POWER INPUT Input...
Page 16
Chapter 1 Introduction Drawing No. LP1182 NT5006-DM2 DIMENSIONS In inches [mm] Revision A NT5006-DM2 DIMENSIONS In inches [mm] DIN rail 4.83 [122.6] 1.65 [41.9] 0.39 0.38 [9.7] [10.0] 4.19 3.85 5.11 [106.3] [97.8] [129.8] 0.2 [5.5] Optional panel mount 0.53 5.11 [129.8] [13.4] 1.65...
Page 17
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5008 Specifications NT5008 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.5M Hours IP20 3.85" (97.8 1.65" (41.9 mm) 5.11" (129.8 mm) 1.09 lbs. (0.50 kg) DIN rail or optional panel mount POWER Input...
Page 18
Chapter 1 Introduction Drawing No. LP1182 NT5008 DIMENSIONS In inches [mm] Revision A NT5008 DIMENSIONS In inches [mm] DIN rail 1.65 [41.9] 4.83 [122.6] 0.39 0.38 [9.7] [10.0] 5.11 [129.8] 4.19 [106.3] 0.2 [5.5] Optional panel mount 1.65 0.53 5.11 [129.8] [41.9] [13.4] 0.39...
Page 19
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5008-DM2 Specifications NT5008-DM2 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.5M Hours IP20 3.85" (97.8 1.65" (41.9 mm) 5.11" (129.8 mm) 1.16 lbs. (0.52 kg) DIN rail or optional panel mount POWER INPUT Input...
Page 20
Chapter 1 Introduction Drawing No. LP1182 NT5008-DM2 DIMENSIONS In inches [mm] Revision A NT5008-DM2 DIMENSIONS In inches [mm] DIN rail 1.65 4.83 [122.6] [41.9] 0.39 0.38 [9.7] [10.0] 5.11 4.19 [129.8] 3.85 [106.3] [97.8] 0.2 [5.5] Optional panel mount 0.53 1.65 5.11 [129.8] [13.4]...
Page 21
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5008-FX2 Specifications NT5008-FX2 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.2M Hours IP20 3.85" (97.8 2.25" (57.1 mm) 5.11" (129.8 mm) 1.38 lbs. (0.62 kg) DIN rail or optional panel mount POWER INPUT Input...
Page 22
Chapter 1 Introduction Drawing No. LP1182 NT5008-FX2 DIMENSIONS In inches [mm] Revision A NT5008-FX2 DIMENSIONS In inches [mm] DIN rail 2.25 [57.1] 4.83 [122.6] 0.99 0.38 [9.7] [25.1] 5.11 [129.8] 5.62 4.19 3.85 [142.7] [106.3] [97.8] 0.2 [5.8] Optional panel mount 0.53 2.25 5.11 [129.8]...
Page 23
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5008-GX2 Specifications NT5008-GX2 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.2M Hours IP20 3.85" (97.8 2.25" (57.1 mm) 5.11" (129.8 mm) 1.38 lbs. (0.62 kg) DIN rail or optional panel mount POWER INPUT Input...
Page 24
Chapter 1 Introduction Drawing No. LP1182 NT5008-GX2 DIMENSIONS In inches [mm] Revision A NT5008-GX2 DIMENSIONS In inches [mm] DIN rail 2.25 [57.1] 4.83 [122.6] 0.99 0.38 [9.7] [25.1] 5.11 [129.8] 5.62 4.19 3.85 [142.7] [106.3] [97.8] 0.2 [5.8] Optional panel mount 0.53 2.25 5.11 [129.8]...
Page 25
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5010-DM2 Specifications NT5010-DM2 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.5M Hours IP20 3.85" (97.8 1.65" (41.9 mm) 5.11" (129.8 mm) 1.16 lbs. (0.52 kg) DIN rail or optional panel mount POWER INPUT Input...
Page 26
Chapter 1 Introduction Drawing No. LP1182 NT5010-DM2 DIMENSIONS In inches [mm] Revision A NT5010-DM2 DIMENSIONS In inches [mm] DIN rail 1.65 [41.9] 4.83 [122.6] 0.39 [10.0] 0.38 [9.7] 5.11 [129.8] 4.19 3.85 [106.3] [97.8] 0.2 [5.5] Optional panel mount 0.53 1.65 5.11 [129.8] [13.4]...
Page 27
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5010-FX2 Specifications NT5010-FX2 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.2M Hours IP20 3.85" (97.8 2.25" (57.1 mm) 5.11" (129.8 mm) 1.38 lbs. (0.62 kg) DIN rail or optional panel mount POWER INPUT Input...
Page 28
Chapter 1 Introduction Drawing No. LP1182 NT5010-FX2 DIMENSIONS In inches [mm] Revision A NT5010-FX2 DIMENSIONS In inches [mm] DIN rail 2.25 [57.1] 4.83 [122.6] 0.99 [25.1] 0.38 [9.7] 5.11 [129.8] 5.62 [142.7] 4.19 3.85 [106.3] [97.8] 0.2 [5.8] Optional panel mount 0.53 2.25 5.11 [129.8]...
Page 29
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5010-GX2 Specifications NT5010-GX2 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.2M Hours IP20 3.85" (97.8 2.25" (57.1 mm) 5.11" (129.8 mm) 1.38 lbs. (0.62 kg) DIN rail or optional panel mount POWER INPUT Input...
Page 30
Chapter 1 Introduction Drawing No. LP1182 NT5010-GX2 DIMENSIONS In inches [mm] Revision A NT5010-GX2 DIMENSIONS In inches [mm] DIN rail 2.25 [57.1] 4.83 [122.6] 0.99 [25.1] 0.38 [9.7] 5.11 [129.8] 5.62 [142.7] 4.19 3.85 [106.3] [97.8] 0.2 [5.8] Optional panel mount 0.53 2.25 5.11 [129.8]...
Page 31
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5016 Specifications NT5016 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.2M Hours IP20 5.36" (136.1 2.25" (57.1 mm) 5.11" (129.8 mm) 1.31 lbs. (0.60 kg) DIN rail or optional panel mount POWER INPUT Input...
Page 32
Chapter 1 Introduction Drawing No. LP1182 NT5016 DIMENSIONS In inches [mm] Revision A NT5016 DIMENSIONS In inches [mm] DIN rail 2.25 4.83 [122.6] [57.1] 0.99 0.38 [9.7] [25.2] 5.70 5.36 [144.9] 5.11 [136.1] [129.8] 0.2 [5.7] Optional panel mount 0.53 5.11 [129.8] 2.25 [13.4]...
Page 33
Drawing No. LP1182 Chapter 1 Introduction Revision A NT5018-DM2 Specifications NT5018-DM2 Specifications MECHANICAL MTBF Ingress Height Width Depth Weight Installation Options Protection 1.2M Hours IP20 5.36" (136.1 2.25" (57.1 mm) 5.11" (129.8 mm) 1.36 lbs. (0.62 kg) DIN rail or optional panel mount POWER INPUT Input...
Drawing No. LP1182 Chapter 1 Introduction Revision A LEDs LEDs Data ports have two LEDs labeled LNK and ACT. The LNK LED indicates link and the ACT LED indicates port activity status. The table below describes the operating modes: COLOR DESCRIPTION Green Power is On...
Contents of Package Chapter 2 Installation Contents of Package Carefully remove the switch and accessories from the shipping container and inspect them for damage. Contact Red Lion immediately if any damage is discovered. Please verify that the box contains the following items:...
Chapter 2 Installation Drawing No. LP1182 Mounting the NT5000 Unit Revision A DIN Rail Removal Instructions Remove the switch from standard 35mm DIN rail as shown in the diagram above. 1. Ensure power from the power source is off. 2. Disconnect power and ground wires. 3.
PWR2 inputs must be connected to separate DC voltage sources. This unit will draw power from the supply with higher voltage. Recommended 24 VDC power supply, similar to Red Lion’s P/N NTPS-24-1-3. Verify that the proper input voltage is connected to the NT5000 before powering on the unit. Applying AC power to a DC NT5000 unit will damage the unit.
Cat5e straight through or crossover cable with a minimum length of one meter and a maximum length of 100 meters. Red Lion recommends the use of pre-manufactured Cat5e cables to ensure the best performance. If this is not an option and users must terminate their own ends on the Cat5e cables, one of the two color coded standards shown to the right should be utilized.
Drawing No. LP1182 Chapter 2 Installation Revision A Connecting to the Ethernet Port (Fiber, SFP) Connecting to the Ethernet Port (Fiber, SFP) For FX/GX models, remove the dust cap from the fiber optic connectors and connect the appropriate fiber optic cables. The TX port on the FX/GX models should be connected to the RX port of the far end station.
Chapter 2 Installation Drawing No. LP1182 Cleaning Revision A Terminal The following configuration should be used in terminal emulation program: z USB-A to Micro-B USB Cable to connect to computer USB port z Port Settings: 115200 bps z Data Bits: 8 ...
Drawing No. LP1182 Chapter 3 Accessing the Web Software Interface Revision A Chapter 3 Accessing the Web Software Interface 1. Launch a web browser and enter the IP address of the device into the address bar. By default, the DHCP Client is enabled and if DHCP times out the device can be reached using the fallback address 192.168.1.201.
Service Information We sincerely hope that you never experience a problem with any of our products. If you do need service, call Red Lion at 1-877-432-9908 for Technical Support. A trained specialist will help you determine the source of the problem. Many problems are easily resolved with a single phone call.
LIMITED WARRANTY (a) Red Lion Controls Inc. (the “Company”) warrants that all Products shall be free from defects in material and workmanship under normal use for the period of time provided in “Statement of Warranty Periods” (available at www.redlion.net) current at the time of shipment of the Products (the “Warranty Period”).
Need help?
Do you have a question about the N-Tron Series and is the answer not in the manual?
Questions and answers