Evaluation kit for ra6m4 microcontroller group (37 pages)
Summary of Contents for Renesas Y-G-HYBRID-PLC-RF
Page 1
All information contained in these materials, including products and product specifications, represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp. without notice. Please review the latest information published by Renesas Electronics Corp.
Page 2
Renesas Electronics disclaims any and all liability for any damages or losses incurred by you or any third parties arising from the use of any Renesas Electronics product that is inconsistent with any Renesas Electronics data sheet, user’s manual or other Renesas Electronics document.
Page 3
Unit Products The following usage notes are applicable to all Microprocessing unit and Microcontroller unit products from Renesas. For detailed usage notes on the products covered by this document, refer to the relevant sections of the document as well as any technical updates that have been issued for the products.
Page 4
Renesas or its affiliates shall in no event be liable for any loss of profit, loss of data, loss of contract, loss of business, damage to reputation or goodwill, any...
Assumptions and Advisory Notes ......................8 Hybrid PLC and Sub-GHz Communication Evaluation Kit Overview ........9 Y-G-HYBRID-PLC-RF Solution Kit Contents................12 Y-G-HYBRID-PLC-RF Ordering Information ................13 Y-G-HYBRID-PLC-RF Kit Hardware Architecture ..............13 Block Diagram ............................13 MCU ..............................14 Power Line Communication ........................14 Sub-GHz RF Communication ........................
Page 6
USB to RX651 Host Control (RF) and PMOD2 to R9A06G037 (PLC Only) ......... 31 MyPages Software Registration ..................... 33 Schematics ..........................34 Y-G-HYBRID-PLC-RF Communication Board ..................34 Y-G-HYBRID-PLC-RF Communication Line Coupler ................41 10. System BOM list ........................42 10.1 Y-G-HYBRID-PLC-RF Communication Board ..................42 10.2 Y-G-HYBRID-PLC-RF Communication Board ..................45 11.
Page 7
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual Figures Figure 1. Y-G-HYBRID-PLC-RF Communication Board Top Side ..............9 Figure 2. Y-G-HYBRID-PLC-RF Communication Board Bottom Side .............. 9 Figure 3. Y-G-HYBRID-PLC-RF Communication Board ................. 12 Figure 4. Y-G-HYBRID-PLC-RF Line Coupler Box ..................12 Figure 5.
Page 8
Table 24: DIP2 Switch Control for USB to RX651 Host Control (RF) and PMOD2 to R9A06G037 Connection (PLC Only) ............................... 32 Table 25: Y-G-HYBRID-PLC-RF Communication Board BoM list..............45 Table 26: Y-G-HYBRID-PLC-RF Communication Line Coupler BoM list ............45 Rev 1.00 Page 4 of 46...
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual Glossary Alternating Current Acknowledge Bill of Materials Bits Per Second CMOS Complementary Metal-Oxide Semiconductor Cyclic Redundancy Check Carrier Sense Multiple Access – Collision Avoidance CSMA-CA Direct Current DCDC Direct Current - Direct Current...
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual Serial Peripheral Interface Tamb Ambient Temperature Transmit Data UART Universal Asynchronous Receiver-Transmitter Universal Serial Bus Voltage Table 1. List of Abbreviations and Acronyms Rev 1.00 Page 6 of 46 Jul.14.22...
1.2A output current, barrel plug centre positive 2.1mm x 5.5mm output connector • 18W maximum output power, size of 77mm x 47.5mm x 35mm AC cable: The Y-G-HYBRID-PLC-RF communication kit comes provided with a 2 Pin Euro Plug to Figure 8 (C7) Power Cable with the following ratings: •...
Power Line Communication Line Coupler. 1.6 Protection of the Sub-GHz RF Analog Front End. The Y-G-HYBRID-PLC-RF solution kit contains an FEM module on the AFE of the Sub-GHz RF. Directly connecting two Y-G-HYBRID-PLC-RF communication boards with an un-attenuated SMA cable will cause permanent damage the to the boards.
2. Hybrid PLC and Sub-GHz Communication Evaluation Kit Overview The Y-G-HYBRID-PLC-RF communication system has been built around the proven hardware for PLC, Cool Phoenix 3 - R9A06G037, and the proven hardware for Sub-GHz RF for IEEE802.15.4 SUN FSK / WiSUN, the RAA604S00 devices.
Page 14
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual The key features of the Y-G-HYBRID-PLC-RF communication system are categorized in four groups (consistent with the architecture of the board) as follows: MCU: Host MCU • R5F5651EDDFP#30 MCU (referred to as RX651 MCU) •...
Page 15
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual System Control and Ecosystem Access • One 15 V input source • External power supply (using barrel connector, J5) • E20 / E2 / E2 Lite Emulator programmer/debugger connector (J3) •...
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual 3. Y-G-HYBRID-PLC-RF Solution Kit Contents The following is a list of items which are included in the Y-G-HYBRID-PLC-RF Communication kit: • Y-G-HYBRID-PLC-RF communication board as shown in Figure 3. Y-G-HYBRID-PLC-RF Communication Board •...
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual The following is a list of items which are not included in the Y-G-HYBRID-PLC-RF kit: • RF SMA Type Connector Cable • E2, E2 Lite or E20 Emulator. https://www.renesas.com/us/en/design-support/development-tools#dev-tools-list If these are required, please order these separately.
Figure 6. Y-G-HYBRID-PLC-RF Board Architecture 5.2 MCU The MCU used on the board is the Renesas RX651 (orderable part name: R5F5651EDDFM#30), a 32-bit microcontroller with RXv2 Core, large-capacity RAM, and enhanced security, connectivity and HMI capabilities. For more information, please refer to: https://www.renesas.com/RX651...
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual https://www.renesas.com/QS3257QG8 The wide bus to the Sub-GHz wireless modem LSI RAA604S00 is controlled via a high-speed CMOS 2:1 x 10 switch (orderable part name: QS3VH16210PAG8) https://www.renesas.com/QS3VH16210PAG8 5.7 Power Supply The board is designed to work from an external 15V power supply. This voltage is issued to the PLC power amplifier.
PMOD2_VDD USB Power Status CPX3 GPIO10 Rx LED CPX3 GPIO11 Tx LED Table 2: LED Connections 6. Board Overview Figure 7. Y-G-HYBRID-PLC-RF Board Main Board Areas 6.1 Board connections Figure 8. Y-G-HYBRID-PLC-RF Board Overview Rev 1.00 Page 16 of 46...
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual 6.2 J1 PLC Line Coupler Connector The line coupler connector provides a galvanic isolated connection to the mains power line for sending/receiving the PLC signals. Additionally, zero-crossing feedback is issued to the Y-G-HYBRID-PLC- RF board.
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual 6.6 J5 Power Supply Barrel Connector (15V / 2A) The board is powered from an external 15V DC power supply, connecting via a 3.5mm barrel connector. Figure 9. J5 Power Supply Barrel Connector 6.7 J6 RX651 Auxiliary Connector...
Table 9: Jumper J10 6.11 J11 Jumper Setting for PLC Frequency Bands, CENELEC/FCC/ARIB The Y-G-HYBRID-PLC-RF communication system allows for optimising the power line analog front end. For low impedance loads in the CENELEC-A band, the PLC transmission output power can be increased by inserting an L3 inductor in series with the transmission output.
The PMOD2 allows an external MCU board using a full type 3A male connector. The serial communication signals are galvanically isolated from the rest of the board, therefore Peripheral Vcc must be providing power (maximum 5V). Note that only TX/RX and RESET are connected on the Y-G-HYBRID-PLC-RF communication system.
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual mode or set the switch accordingly, below details the switch settings. Section 7: Operation Modes describes the settings for each operation mode. DIP2 RX651 port Controls active switch switch SW 1...
Table 16: Switch 3 Control 6.17 Reset Circuitry The Y-G-HYBRID-PLC-RF communication system contains a single reset button, S3. This button can be used to reset either the RX651 device or the power line modem LSI R9A06G037 depending on the active switch settings described in Section 6 Board Overview.
R9A06G037 running a PLC SimpleMAC program and sub-GHz RF evaluation via Renesas RF Test Studio. (Please refer to the Y-G-HYBRID-PLC-RF quick start guides for information on the operation). This allows the user to quickly evaluate the Y-G-HYBRID-PLC-RF powerline and sub-GHz RF communication evaluation board using the G3 PLC PHY or SUN FSK RF PHY Layer evaluation software.
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual the USB connection is connected to the RX651 and a UART interface is used to connect the RX651 and power line modem LSI - R9A06G037, in this configuration the Sub-GHz wireless modem LSI RAA604S00 is not used.
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual 7.3 USB to RX651 Host Control (RF Only) This configuration is used when there is a sample application running on the RX651 and the user either wants to develop on the RX651 or use the functionality of the RX651 to control the sub-GHz wireless modem LSI RAA604S00.
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual Table 18: DIP2 Switch Control for USB to RX651 Host Control Connection (RF Only) 7.4 USB to RX651 Host Control (Hybrid) This configuration is used when there is a sample application running on the RX651 and the user either wants to develop on the RX651 or use the functionality of the RX651 to control the power line modem LSI - R9A06G037, which in turn also controls the sub-GHz wireless modem LSI RAA604S00.
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual DIP2 Switch Setting Table 19: DIP2 Switch Control for USB to RX651 Host Control (Hybrid) 7.5 USB to R9A06G037 (PLC Only) This configuration is used when there is no requirement for a sample application running on the RX651 and the user wants to bypass the RX651 and connect directly to the power line modem LSI - R9A06G037.
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual Figure 20: USB to R9A06G037 Connection (PLC Only) Block Diagram. The following table shows the DIP2 switch settings for this mode. DIP2 Switch Setting ON/OFF Table 20: DIP2 Switch Control for USB to R9A06G037 Connection (PLC Only) 7.6 USB to R9A06G037 (Hybrid)
R9A06G037 using the PMOD standard interface. The PMOD standard interface is available on most of the Renesas starter kits allowing users to develop on a wide range of application processors using standard starter kits. The interface to the R9A06G037 is then via the appropriate Serial Command Specifications.
HOST MCU such as the RA6M4 and connect a host processor easily to the R9A06G037 using the PMOD standard interface. The PMOD standard interface is available on most of the Renesas starter kits allowing users to develop on a wide range Rev 1.00 Page 30 of 46 Jul.14.22...
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual of application processors using standard starter kits. The interface to the R9A06G037 is then via the appropriate Serial Command Specifications. This configuration is required for: • G3-PLC Hybrid Sample Applications (For RA6M4 – EK-RA6M4) •...
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual Control (RF) and PMOD2 to R9A06G037 Connection (PLC Only). In this mode the USB connection is connected to the RX651 which has an SPI interface connection to control the sub-GHz wireless modem LSI - RAA604S00 and the PMOD2 has a UART interface to connect and control the power line modem LSI - R9A06G037 via the appropriate Serial Command Specifications.
Software packages are available for this communication platform. The protocol stacks from Renesas are available via “MyPages”, please register and sign up to receive protocol updates from Renesas. To make these packages available Renesas will need to complete an ICP and export control check. Registration can be done following this link: https://www2.renesas.eu/products/micro/download/index.html/auth/register...
Hybrid PLC and Sub-GHz Communication Evaluation Kit Y-G-HYBRID-PLC-RF User's Manual 9.2 Y-G-HYBRID-PLC-RF Communication Line Coupler Rev 1.00 Page 41 of 46 Jul.14.22...
Need help?
Do you have a question about the Y-G-HYBRID-PLC-RF and is the answer not in the manual?
Questions and answers