Products Solutions Services KA01353D/06/EN/01.17 71382752 Brief Operating Instructions Heat Transmitter with ultrasonic time-of-flight sensor These instructions are Brief Operating Instructions; they are not a substitute for the Operating Instructions pertaining to the device. Transmitter Brief Operating Instructions Contain information about the transmitter.
Page 2
Heat Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
Page 3
These Brief Operating Instructions are the Transmitter Brief Operating Instructions. The "Sensor Brief Operating Instructions" are available via: • Internet: www.endress.com/deviceviewer • Smart phone/tablet: Endress+Hauser Operations App Detailed information about the device can be found in the Operating Instructions and the other documentation: • Internet: www.endress.com/deviceviewer...
Heat Document information Document information Symbols used 1.1.1 Safety symbols Symbol Meaning DANGER! DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in WARNING serious or fatal injury.
Page 6
Document information Heat Symbol Meaning Protective Earth (PE) A terminal which must be connected to ground prior to establishing any other connections. The ground terminals are situated inside and outside the device: • Inner ground terminal: Connects the protectiv earth to the mains supply.
Heat Basic safety instructions Basic safety instructions Requirements for the personnel The personnel must fulfill the following requirements for its tasks: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task. ‣ Are authorized by the plant owner/operator.
Residual risks WARNING The electronics and the medium may cause the surfaces to heat up. This presents a burn hazard! ‣ For elevated fluid temperatures, ensure protection against contact to prevent burns.
Heat Product description Product description The device consists of a transmitter and a sensor. The device is available as a compact version: The transmitter and sensor form a mechanical unit. For detailed information on the product description, see the Operating Instructions for...
Installation Heat 4.1.1 Nameplate Prosonic Flow A0035198 1 Sensor nameplate, subject to mandatory verification Name of the sensor Nominal diameter of sensor K-factor Software version Accuracy class Environmental class Minimum flow rate Permanent flow rate Maximum flow rate Medium temperature...
Page 11
Heat Installation 4.2.1 Sealing the transmitter A0025239 Pull the wire through the bore in the housing and through the screw head. In doing so, ensure that the wire is taut and there is no leeway for the screw to loosen.
Electrical connection Heat Electrical connection NOTICE The measuring device does not have an internal circuit breaker. ‣ For this reason, assign the measuring device a switch or power-circuit breaker so that the power supply line can be easily disconnected from the mains.
Page 13
Heat Electrical connection 5.1.3 Terminal assignment Transmitter Pulse output connection version Order code for "Output", option P 27 A A0019528 2 Pulse output terminal assignment Power supply: DC 24 V Pulse output Pulse/frequency output connection version Order code for "Output", option K...
Page 14
Electrical connection Heat 5.1.4 Preparing the measuring device NOTICE Insufficient sealing of the housing! Operational reliability of the measuring device could be compromised. ‣ Use suitable cable glands corresponding to the degree of protection. Remove dummy plug if present. If the measuring device is supplied without cable glands: Provide suitable cable gland for corresponding connecting cable.
Heat Electrical connection Connecting the measuring device NOTICE Limitation of electrical safety due to incorrect connection! ‣ Have electrical connection work carried out by appropriately trained specialists only. ‣ Observe applicable federal/national installation codes and regulations. ‣ Comply with local workplace safety regulations.
Page 16
Electrical connection Heat 3 mm 10 (0.4) A0030223 4 Device versions with connection example. Engineering unit mm (in) Cable ‣ Connect the cable in accordance with the terminal assignment → 13. 5.2.2 Ensuring potential equalization Prosonic Flow E...
Heat Electrical connection Special connection instructions 5.3.1 Connection examples Pulse/frequency output 12345 A0028761 5 Connection example for pulse/frequency output (passive) Automation system with pulse/frequency input (e.g. PLC) Power supply Transmitter: Observe input values Ensuring the degree of protection The measuring device fulfills all the requirements for the IP66/67 degree of protection, Type 4X enclosure.
Operation options Heat To ensure that moisture does not enter the cable entry: Route the cable so that it loops down before the cable entry ("water trap"). A0029278 Insert dummy plugs into unused cable entries. Post-connection check Are cables or the device undamaged (visual inspection)? ...
Heat System integration Structure and function of the operating menu 6.2.1 Structure of the operating menu Operating menu for operators and maintenances Language Operation task-oriented Setup Diagnostics Operating menu for experts Expert function-oriented A0014058-EN 6 Schematic structure of the operating menu 6.2.2...
Commissioning Heat Commissioning Function check Before commissioning the measuring device: ‣ Make sure that the post-installation and post-connection checks have been performed. • "Post-installation check" checklist • "Post-connection check" checklist → 18 Configuring the measuring device The Setup menu with its submenus enable fast commissioning of the measuring device. The submenus contain all the parameters required for configuration, such as parameters for measurement or communication.
Page 21
Heat Diagnostic information Xxxxxx/…/…/ Device name: Xxxxxxx Mass flow: kg/h 12.34 Device tag: Xxxxxxx Volume flow: 12.34 ³ m /h Status signal: Function check (C) Xxxxxx Diagnostics 1: C485 Simu... Remedy information: Deactivate... Failure (F) Access status tooling: Mainenance Operation...