10.4.2

Response of outputs to errors

The failsafe mode of the pulse, frequency and status output can be set differently via
the DeviceCare or FieldCare operating program.
Error response mode of the pulse and status output
Output
Failsafe mode
Pulse output
The failsafe mode of the pulse output can be set differently using the DeviceCare or
FieldCare operating program:
FALLBACK VALUE
Signal output → No pulses
ACTUAL VALUE
Fault is ignored, i.e. normal measured value output on the basis of ongoing flow
measurement
Notice messages do not have any effect on the pulse output! See information on.
Frequency output
The failsafe mode of the frequency output can be set differently using the DeviceCare
or FieldCare operating program.
Status output
The assignment of the status output can be defined via the DeviceCare or FieldCare
operating program.
In the event of a fault, notice message or power supply failure → the status output is not
conductive
10.4.3

Software history

Date
Software
Changes to software
version
08.2014 3.00.zz
• Original software
• Compatible with DeviceCare
08.2012 1.01.XX
No software modifications
01.2011
New functionality:
04.2007 1.01.00
• Selection of a measuring mode for the pulse output
• New limit value switch for the status output with the
option of specifying the switch-on value and switch-off
point individually
• Choice of operating mode for pressure shock suppression
• New option to clear the error memory
12.2003 1.00.00
• Original software
• Compatible with FieldCare
10.5

Pending diagnostic events

The Diagnostics menu allows the user to view the current diagnostic event and the
previous diagnostic event separately.
To call up the measures to rectify a diagnostic event:
Via DeviceCare and FieldCare operating tool (→
Other pending diagnostic events can be displayed in the Diagnostic list