Maintenance and Service

MAINTENANCE AND SERVICE
EN
3.1 To Replace the Solarmatik Cartridge
• Remove the existing cartridge according to Figure 7a and Figure 7b and insert a new one.
• Take the new cartridge and thread the potentiometer cable under the wire frame before placing the cartridge
in its slot inside the mask. Press down the wireframe and make sure the leading edge of the wireframe is
attached under the fixing hooks Figure 7b.

3.2 To Replace Lenses

• If the front surface lens is damaged (cracking, scratching, dirt, scoring, etc.), replace the lens.
• If the inner surface lens is damaged (cracking, scratching, dirt, scoring etc.), replace the lens.
• Place your finger in the recess at the bottom edge of the frame and flex the frame upward
until it comes off one edge Figure 7.

3.3 Cleaning

• Wipe the mask with a soft cloth. Clean the cartridge surface regularly. Do not use strong solvents for cleaning.