Special Functions Menu; Enter In The Special Functions Menu; Diagnostic Program Of Sensors; Statistic Program - Fasep B222 User Manual

Table of Contents

Advertisement

Fasep 2000 srl
Balatron 222/212: User's Manual
8

SPECIAL FUNCTIONS MENU

8.1

Enter in the special functions menu

Switch on the wheel balancer. Press <SET> before SOF X.XX will disappear.
CAL
Calibration of wheel balancer
CAL tSt
CAL rod
SEn Sor
StA tiS
USr Set
tEc Set
Ser nuM
Act Cod
8.2

Diagnostic program of sensors

Switch on the wheel balancer. Press <SET> before SOF X.XX will disappear. Select Sen Sor and press <SET>.
rPM
Balancing speed
PS1
PS1 voltage
PS2
PS2 voltage
tO
Encoder is in the zero position
PoS
Angle of position sensor(from 0 to 255)
dIS
Value of distance sensor
dIA
Value of diameter sensor
OUT
Value of width sensor
Cou
Safety cover is open or closed
PED
Air pedal (only PL version)
AIR
Pressure guage (only PL version)
8.3

Statistic program

Switch on the wheel balancer. Press <SET> before SOF X.XX will disappear. Select Sta tis and press <SET>.
tOt
SUC
c11 0s
from 11 to 17
]17 0s
CAL
pne
8.4

User Setup

Switch on the wheel balancer. Press <SET> before SOF X.XX will disappear. Select USa SET and press <SET>.
ScA LE Set 1 or 5 grams step (0.05/0.25 ounces).
Cut oFF
Uni Out
Uni Umb
Fin AL
biP
EME StP
Cou Er
On = the motor starts only if the safety cover is closed;
Aut = closing of safety cover the motor starts automatically.
rod in Enable/Disable distance input system.
rod out
STE P Increase distance/width measure.
PNE U Enable/Disable PL system.
SCR EEN
VOI CE Enable/Disable voice system.
Snr
Sensibility to external vibration.
Tim er Input system speed.
Fas t
Enable/Disable fast cycle.
APS
Enable/Disable automatic position system.
ADM IN Enable/Disable Admin mode.
OPT
Set minimum tire matching level.
rES Et Load Factory Setup.
Control of the calibration of electronic sensors
Calibration of electronic input sensors
Diagnostic of sensors
Statistic about the use of machine
User setup
Technical Setup
Serial number
Inserting Activation Codes
Total number of spin
Percent of runs with a good result
Percent of wheels with diameter <11"
Percent of wheels with the indicated diameter
Percent of wheels with diameter >17"
Number of calibrations
Number of PL test (only PL version)
Set minimum weight to be displayed.
Unit of measure for the width (0=inch, 1=millimeters).
Unit of measure for the weight (0= grams, 1=once).
Display of final (0 = normal, 1 = blink, 2= Go OD).
Enable/Disable beep in position.
Motor brakes in case of emergency stop (On or OFF) (OFF: motor power is cut).
OFF = safety cover is not installed;
Enable/Disable width input system.
Screen saver selection from 1 to 5 (0 = disable).
8-1
Rev. 1.8
23 January 2020

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B212B112

Table of Contents