Specifications

Rated Power Supply:
Rated Input:
Color System:
Operating Temperature:
Relative Humidity:
Altitude:
Dimensions:
Weight:
Recording System
Sampling
Data Compression
Compression Unit
Resolution
Recording Device
Video Input:
Monitor Output:
Throughout Output:
Audio Input:
Audio Output:
Microphone Input:
Timer Program:
Memory Backup:
CONNECTORS
ALARM IN(1-9) Input:
CLOCK ADJ Input:
REC Input:
EMERGENCY Input:
GND:
MODE OUT(1-5) Output:
DC 12V OUT Output:
CALL OUT/CALL OUT GND:
Rating:
MODE OUT(1-5)
ALARM IN / CLOCK ADJ /
REC/EMERGENCY
CALL OUT /
CALL OUT GND
RS-232C
LAN
Accessories
AC power cord
COMPACT FLASH slot cover (mounted on unit)
Compact Flash Card recording format
Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Specifications
94
AC 100-240V 50/60Hz
0.60 - 0.30A (100-240V)
NTSC type color system.
41°F-104°F (5°C to 40°C).
Max.80(%)
Max.2000(m)
300(Width) x 350(Depth) x 88(Height)(mm).
5.0kg
Digital recording method using WAVELET compression.
13.5MHz
WAVELET
Field
684 x 240
250GB HDD
9 Input BNC-Connector:
1.0 V(p-p), 75 ohms.
S-Connector:
Y-Signal: 1.0 V(p-p), 75 ohms.
C-Signal: 0.3 V(p-p), 75 ohms.
2 Output BNC-Connector:
1.0 V(p-p), 75 ohms.
RCA-Pinplug:
1.0 V(p-p), 75 ohms.
9 Output BNC-Connector:
1.0 V(p-p), 75 ohms.
RCA-Pinplug:
308 mV(rms), 50 kohms.
2 Output RCA-Pinplug:
308 mV(rms), 1 kohms.
3.5mm minijack:
0.346 mV(rms), 600 ohms.
Ø
8 programs-Daily start and stop time for one week x 3set.
Lasts for more than 1 month.
Terminal for starting alarm recording.
Terminal for adjusting clock.
Terminal for start recording.
Terminal for start emergency recording.
Terminal for ground.
Terminal for indication of recording selected mode.
Terminal for DC 12V OUT. Max. Drive current 350mA DC. ( 350mA : 11.5 V typ ± 1.5 V )
Terminal for external warning device.
Active:
"Low" Level.
Non active: Open.
Active:
When terminals are short-circuited
or "Low" Level voltage is applied.
Non active: Open.
Active:
ON.
Non active: Open.
RS-232C (D-SUB 9pin) connector for connection with personal computer.
Connector form:
RJ-45
Physical interface:
10BASE-T
1
1
Original format (FSM2)
Max. Drive current 7mA DC.
Max. Voltage +24V DC.
Max. Drive current 7mA DC.
Max. Voltage +24V DC.