Table 8. Span Status Fields and Descriptions (Continued)
Field
Description
DS-1
The number of seconds during which the DS-1 input signal was absent
24-Hour UAS
(125 or more consecutive 0s). This value is a running total of the last 24
Count
Hours.
DS-1 Frame
Type of DS-1 framing detected on the input stream (SF, ESF, Unframed or
type
No Activity). This value is a running total of the last 24 Hours.
DS-1 Code
Type of DS-1 line coding used (AMI, B8ZS, AMI: Zero Byte Time Slot
type
Interface[ZBTSI] or B8ZS: ZBTSI). The latter two conditions indicate the
code type that is being received when HiGain is set to its ZBTSI mode. In
either the AMI or B8ZS DS-1 code mode, the selected code is displayed
when in auto mode, the code type displayed is what is being received.
(Auto is not available when attached to HLU-231 List 8D, HLU-319 List 5D,
or HLU-388 List 5D.) This value is a running total of the last 24 Hours.
S
S
YSTEM
The System Settings screen allows you to analyze and view configurable
parameters.
Provisioning from the remote is allowed when connected to
particular HiGain line units. See the HiGain Line Unit technical
practice to determine whether remote provisioning is
allowed.
1
Type
Settings screen
The HRU-402 System Settings screen will appear different
from the screen shown below if the HRU-402 is locally logged
in. When remotely logged in and attached to an HLU-231
List 8D, an HLU-319 List 5D, or an HLU-388 List 5D, some of
the settings will not be shown.
HRU-402 List 1A
ETTINGS
from the Remote Terminal Main menu to view the System
(Figure 15 on page
December 8, 1998
Initializing the Maintenance Terminal Screens
34):