150-402-111-02
HI-GAIN HLU-231
Figure 10. HiGain HLU-231 Remote Terminal Main Menu
3
At this point, you may choose to terminate the remote session by pressing
I
for remote logoff. Terminating the remote session allows other units
in the circuit, such as doublers, to initiate a remote login.
This is necessary because a HiGain circuit only supports one remote
login session at a time. An active session at any module (other than the
HLU) prohibits active sessions at all other circuit modules.
The HRU-402 automatically performs a remote logoff if no
activity at the keyboard is detected after five minutes. This
prevents remote login sessions that were not properly
terminated from blocking access to the Craft port at other
locations.
HRU-402 List 1A
REMOTE TERMINAL MAIN MENU (ver V6.2L-8E)
CIRCUIT ID#:
A. VIEW SPAN STATUS
C. SYSTEM SETTINGS
D. LOOPBACK MODE: NONE
E. VIEW PERFORMANCE DATA
F. VIEW PERFORMANCE HISTORY
G. VIEW ALARM HISTORY
H. VIEW SYSTEM INVENTORY
I. REMOTE LOGOFF
December 8, 1998
Navigating the Maintenance Terminal Screens
25