H2TU-R-402 L The H2TU-R-402 List 4F functions as the remote end of a repeaterless T1 ® transmission system when connected to a HiGain HDSL2 line unit (H2TU-C). Setting new standards for interoperability and efficiency, HiGain HDSL2 modules transmit 1.544 Mbps T1 payload on one unconditioned copper pair over the full Carrier Service Area (CSA) range.
NSTALLATION H i G a i n H2TU-R-402 L T A ir G I R E a in Remote enclosure - 2 3 Wear an antistatic wrist strap when installing the H2TU-R. Avoid touching components on the circuit board. Align the H2TU-R with the enclosure slot guides and slide the unit in. Push the unit back until it touches the backplane card-edge connector.
H2TU-C. Once logged on, you can view system settings and inventory, initiate loopbacks, monitor performance, and configure the circuit. Monitor Performance Event Log Config Inventory Report Rlogon Help +------------------------------------------+ ADC DSL Systems, Inc. HiGain HDSL2 Voice: 800.638.0031 714.832.9924 +------------------------------------------+ ID: xxxx--xxxx--xxxx--xxxx 08/21/2001 06:38:12 H2TU-C System: OK...
Page 6
For more information about the HiGain HDSL2 maintenance screens, refer to the technical practice of the H2TU-C line unit. Copies of technical practices can be downloaded from the ADC website at www.adc.com. To order a hard copy, please contact your sales representative.