Icom IC-R8600 Service Manual page 18

Communications receiver
Hide thumbs Also See for IC-R8600:
Table of Contents

Advertisement

5-4
VU RECEIVE ADJUSTMENT (CONTINUED)
ADJUSTMENT
ADJUSTMENT ITEM DISPLAY
20 VU2 S0 LEVEL
VU2 S-METER
21 VU2 S9 LEVEL
22 VU2 S9+60 LEVEL
23 VU2 dBu –10dB
24 VU2 dBu 0dB
25 VU2 dBu 10dB
26 VU2 dBu 20dB
27 VU2 dBu 40dB
28 VU2 dBu 60dB
29 VU2 dBu 80dB
30 VU12 BPF1 flat ( M)
VU12-flat
31 VU12 BPF1 flat (L)
32 VU12 BPF1 flat (H)
33 VU12 BPF2 flat ( M)
34 VU12 BPF2 flat (H)
35 VU12 BPF3 flat ( M)
36 VU12 BPF3 flat (L)
37 VU12 BPF3 flat (H)
38 VU12 BPF4 flat ( M)
39 VU12 BPF4 flat (L)
40 VU12 BPF4 flat (H)
41 VU12 BPF5 flat ( M)
42 VU12 BPF5 flat (L)
43 VU12 BPF5 flat (H)
44 VU12 BPF6 flat ( M)
45 VU12 BPF6 flat (L)
46 VU12 BPF6 flat (H)
47 VU12 BPF7 flat (L)
48 VU12 BPF7 flat (M1)
49 VU12 BPF7 flat (M2)
50 VU12 BPF7 flat (H)
: The output level of the standard signal generator (SSG) is indicated as the SSG's open circuit.
CONDITION
• Set the test equipment to:
Frequency:
625.0215 MHz
Modulation:
None
Level:
0 dBμ
(–107 dBm)
• Set the test equipment level to:
Level:
+34 dBμ
(–73 dBm)
• Set the test equipment level to:
Level:
+94 dBμ
(–13 dBm)
• Set the test equipment level to:
Level:
–10 dBμ
(–117 dBm)
• Set the test equipment level to:
Level:
0 dBμ
(–107 dBm)
• Set the test equipment level to:
Level:
10 dBμ
(–97 dBm)
• Set the test equipment level to:
Level:
20 dBμ
(–87 dBm)
• Set the test equipment level to:
Level:
40 dBμ
(–67 dBm)
• Set the test equipment level to:
Level:
60 dBμ
(–47 dBm)
• Set the test equipment level to:
Level:
80 dBμ
(–27 dBm)
• Set the test equipment to:
Frequency:
40.0215 MHz
Modulation:
None
Level:
+40 dBμ
(–67 dBm)
• Set the test equipment to:
Frequency:
30.0215 MHz
• Set the test equipment to:
Frequency:
49.9815 MHz
• Set the test equipment to:
Frequency:
65.0215 MHz
• Set the test equipment to:
Frequency:
79.9815 MHz
• Set the test equipment to:
Frequency:
105.0215 MHz
• Set the test equipment to:
Frequency:
80.0215 MHz
• Set the test equipment to:
Frequency:
129.9815 MHz
• Set the test equipment to:
Frequency:
165.0215 MHz
• Set the test equipment to:
Frequency:
130.0215 MHz
• Set the test equipment to:
Frequency:
199.9815 MHz
• Set the test equipment to:
Frequency:
260.0215 MHz
• Set the test equipment to:
Frequency:
200.0215 MHz
• Set the test equipment to:
Frequency:
319.9815 MHz
• Set the test equipment to:
Frequency:
410.0215 MHz
• Set the test equipment to:
Frequency:
320.0215 MHz
• Set the test equipment to:
Frequency:
499.9815 MHz
• Set the test equipment to:
Frequency:
500.0215 MHz
• Set the test equipment to:
Frequency:
580.0215 MHz
• Set the test equipment to:
Frequency:
670.0215 MHz
• Set the test equipment to:
Frequency:
749.9815 MHz
5-6
OPERATION
Touch [SET].
(A beep sounds, and then
another beeps sound 1
seconds later.)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents