A
Uninstall the Scale Control Plus with a PRO3 B
1
– Follow the steps below to uninstall the Scale Control Plus with a type PRO3 B tank.
– The 'Q' on the tank cover is the on / off switch.
1
3
A
2
On/off
B
C
1. Turning off the tank
Turn off the tank using the Q button, but
leave the plug in the socket with the
power switched on.
2. Empty the tank
Activate the boiling water tap
and let the water run cold. Also run the
cold water tap at the same time. Close
the isolation valve (3A) then stop the
boiling water tap.
3. Disconnecting the Scale Control Plus
Unscrew both part B and C and
disconnect the scale control including
the coupling piece and fibre washer at C.