3.2. Turn On

3.2.1. Turn On Module with PWRKEY

Table 7: Pin Definition of PWRKEY
Pin Name
Pin No.
PWRKEY
114
The module can be turned on by driving PWRKEY low for at least 2.5 s after VBAT is powered on.
PWRKEY is pulled up to VBAT internally.
It is recommended to use an open collector driver to control the PWRKEY. A reference circuit is illustrated
in the following figure.
Another way to control the PWRKEY is by using a button directly. A TVS component needs to be placed
nearby the button for ESD protection. Additionally, a 1 kΩ resistor is connected in series to PWRKEY. A
reference circuit is shown in the following figure.
SC200K_Series_Hardware_Design
I/O
Description
Turn on/off the
DI
module
> 2.5 s
R1
4.7 K
Turn-on pulse
Figure 7: Turn On Module with Open Collector Driver
S1
Figure 8: Turn On Module Using Button
Comment
Active low.
Pulled up to VBAT internally.
1K
Q1
R2
47 K
PWRKEY
1K
TVS
Smart Module Series
R3
PWRKEY
37 / 105