PRECAUTIONS FOR PROPER USE
List of Setting Items
• The following items can be set in the product.
For the method of setting each item, refer to the User's Manual for HG-F1 Series.
* The User's Manual can be downloaded from our website.
Item
Emitted beam spot check mode
Teaching
Peak / bottom hold function
Zero set function
Key lock function
<Pro mode settings>
Setting
Display
No.
item
screen
Measurement
display
Response
1
time setting
Output
2
operation
setting
Sensing
3
output setting
(teaching)
Analog output
4
setting
Analog
5
scaling setting
Hysteresis
6
setting
Shift amount
7
setting
External input
8
setting
9
Timer setting
Timer period
10
setting
11
Hold setting
12
ECO setting
13
Reset setting
Refer to the instruction manual for details. The instruction manual can be downloaded from our website.
Enables easy confirmation of the position of the laser beam spot on the workpiece.
Enables the setting of the threshold value. The sensing output setting in the PRO mode enables the
selection of teaching method.
Displays and outputs the peak value or bottom value during a certain time period.
Forcibly sets the current measured value to "zero" (reference value).
Disables key operations.
Used to set the time from when the sensor starts measurement until a measurement value is
finalized and output.
<Default: 100>
Used to set the operation mode of control output.
<Default: L-on>
Used to set the threshold teaching method.
<Default:
>
Used to select analog output as either analog voltage output or analog current output.
<Default: Analog v.oUt>
Used to set optional two points as the upper limit value and the lower limit value for performing
twopoint correction on the analog output before data is output. Set the measured value A as the
lower limit value and the measured value B as the upper limit value.
<Measured value A default: 0, measured value B default: 3,000>
Used to set the hysteresis value.
<Default: 30>
Used to set the threshold value for limit teaching and 1-point teaching.
<Default: 60>
Used to set either the zero setting, teaching, or emission stop function.
<Default: 0SEt>
Used to set whether to use the timer setting of control output.
<Default: non>
Used to set the timer period when "OFF delay timer, ON delay timer, or One-shot timer" is set in
the timer setting.
<Default: 5>
Used to set the digital display, the control output and analog output operation when a measurement
error occurs (insufficient light intensity, saturation of light intensity, out of measurement range).
<Default: oFF>
Used to turn OFF the digital display to save electricity when not operating.
<Default: oFF>
Used to reset all the settings of this product to the factory default settings.
<Default: no>