I.
Supplementary Sheet for User Manual
I.I
Revision history
This supplementary sheet(s) is/are exclusively valid for
Product:
Product Designation:
Product Revision:
The chapters described in this supplementary sheet(s) replace the chapters in
User Manual:
Date of creation:
revision of the user manual:
for the
Product:
Product Designation:
Product Revision:
Chapters not replaced by this supplementary sheet(s) in the original user manual remain valid
without exception. Further supplementary sheets to the original instruction manual are valid in
addition to this supplementary sheet.
This document is protected by copyright.
All rights for layout, content, texts and corporate design are reserved by DLS Schmiersysteme
GmbH, © 2022.
All rights, including those of photomechanical reproduction, duplication and distribution
by means of special processes (e.g. data processing, data carriers and data networks),
even in part and/or in extracts, are reserved by DLS Schmiersysteme GmbH.
The content and technical specifications are subject to change without notice.
This supplementary sheet was created in German language, the present language version is a
translation of the German version of the supplementary sheet.
revision: SG-20220816
FlexxPump 500B with external battery compartment
(FP 500B with ext. battery compartment)
---
09.20
AF-20220112
FlexxPump 500B with external battery compartment
(FP 500B with ext. battery compartment)
---
EN-
01

Advertisement

loading
Need help?

Need help?

Do you have a question about the FlexxPump 500 B and is the answer not in the manual?

Questions and answers

Summary of Contents for DLS FlexxPump 500 B

  • Page 1 Further supplementary sheets to the original instruction manual are valid in addition to this supplementary sheet. This document is protected by copyright. All rights for layout, content, texts and corporate design are reserved by DLS Schmiersysteme GmbH, © 2022. All rights, including those of photomechanical reproduction, duplication and distribution by means of special processes (e.g.
  • Page 2 Two battery holders are also included in the scope of delivery. Depending on re- quirements, either the DLS Schmiersysteme GmbH battery pack 6V, or your own primary cells or rechargeable batteries in sizes R6 (AA) or R14 (baby cells), each with 1.5V voltage, can be used to supply the FP 500B with ext.
  • Page 3 FlexxPump 500 B Continuation sheet Fig. 1: Overview FP 500B with ext. battery compartment Description FlexxPump 500B with external battery compartment (FP 500B with ext. battery compartment) OLED Action area (for actions with the activation and programming key) Activation and programming key...
  • Page 4 FlexxPump 500 B Continuation sheet Technical data Electrics Battery sizes (alkaline or lithium) DLS Schmiersysteme GmbH standard battery pack 6V; 4x R6 with 1.5V or 4x R14 with 1.5V (primary cells or rechargeable batteries) revision: SG-20220816...
  • Page 5 FlexxPump 500 B Continuation sheet 5.2 Assembly and initial filling 1. Condition as delivered The FP 500B with ext. battery compartment is delivered in a cardboard box. Depending on the version ordered, additional accessories such as a battery pack or lubricant cartridge are included.
  • Page 6 FlexxPump 500 B Continuation sheet 3. Remove the housing from the power unit of the FP 500B with ext. battery compartment.  Turn the retaining ring counterclockwise in or- der to remove the upper housing from the power unit.  Remove the upper housing from the power unit.
  • Page 7 FlexxPump 500 B Continuation sheet 5. Mount the upper housing from the pump unit of the FP 500B with ext. battery compartment.  Place the disassembled upper part on the FP 500B with ext. battery compartment and press it onto the pump unit.
  • Page 8 FlexxPump 500 B Continuation sheet 7. Inserting the battery packs  Connect the new battery to the battery cable via the reverse polarity protected plug or insert new batteries into the matching battery holder and connect it to the reverse polarity protected plug.
  • Page 9 FlexxPump 500 B Continuation sheet 7.2. Oil refill & battery change 1. Remove the housing from the power unit of the FlexxPump 500.  Separate the housing from the power unit by turning the retaining ring counterclockwise.  Make sure that no dirt, water or foreign bodies enters the lubricant inlet.
  • Page 10 FlexxPump 500 B Continuation sheet The battery can be changed during normal operation of the FP 500B with ext. battery compartment. FP 250/400/500B with external battery compartment shows Error E3; the red LED flashes every 5 seconds. In the following steps is described how you change the battery.
  • Page 11 FlexxPump 500 B Continuation sheet 3. Inserting the battery packs  Connect the new battery to the battery cable via the reverse polarity protected plug or insert new batteries into the matching battery holder and connect it to the reverse polarity protected plug.
  • Page 12 FlexxPump 500 B Continuation sheet Appendix Dimension sheet and installation dimension revision: SG-20220816...