FlexxPump 500 DLS
Continuation sheet
2.
Continuation sheet for user manual
2.1
Revision history
The present continuation sheet ist only valid for:
Product:
Product designation:
Product revision:
with part-number: 235-511-210; 235-512-210; 235-522-210; 235-523-210;
The chapters described in this continuation sheet replace the chapters in the
Anleitung:
Date of creation:
Revision of the user manual:
for the
Product:
Product designation:
Product revision:
The chapters which are not replaced by this continuation sheet, are still valid without
exception. Further continuation sheets for the original user manual are additional to this
continuation sheet valid.
This document is protected by copyright.
All rights for layout, content, texts and corporate design are reserved by DLS Schmier-
systeme GmbH.
All rights, including those of photo-mechanical reproduction, duplication and distribution
by means of special processes (e.g. data processing, data carriers and data networks),
even in part and/or in extracts, are reserved by DLS Schmiersysteme GmbH.
The content and technical specifications are subject to change without notice.
Revision: 0
FlexxPump 500 DLS
---
235-524-210
FlexxPump 400 DLS
---
09.2019
0
D L S
SCHMIERSYSTEME
D I R E C T
L U B R I C A T I O N
S Y S T E M S
EN-
01

Advertisement

loading

Summary of Contents for DLS FlexxPump 500

  • Page 1 Further continuation sheets for the original user manual are additional to this continuation sheet valid. This document is protected by copyright. All rights for layout, content, texts and corporate design are reserved by DLS Schmier- systeme GmbH. All rights, including those of photo-mechanical reproduction, duplication and distribution by means of special processes (e.g.
  • Page 2 The pistons run force-controlled and counter-rotating. The FlexxPump 500 DLS is available as a version with one lubricant outlet, two outlets, thee outlets or four outlets. The outlets are secured by an integrated non-return valve. Approx. 0.15 cm³...
  • Page 3 SCHMIERSYSTEME D I R E C T L U B R I C A T I O N S Y S T E M S Fig. 1: Overview 500 DLS Description FlexxPump 500 DLS Lubricant outlet/ outlets (different versions possible)
  • Page 4 FlexxPump 500 DLS D L S Continuation sheet SCHMIERSYSTEME D I R E C T L U B R I C A T I O N S Y S T E M S Technical data Lubricant and hydraulic system Volume cartridge...
  • Page 5 L U B R I C A T I O N S Y S T E M S Mounting 1. Delivery state The FlexxPump 500 DLS is delivered in a cardboard box. Depending on the version ordered, further accessories such as a lubri- cant cartridge or additional connection parts are included.
  • Page 6 5. Assembling the housing on the power unit of the FlexxPump 500 DLS.  Place the dismantled housing on the FlexxPump 500 DLS and press it onto the power unit.  Fasten the housing to the power unit by turning the retaining ring clockwise.
  • Page 7 FlexxPump 500 DLS D L S Continuation sheet SCHMIERSYSTEME D I R E C T L U B R I C A T I O N S Y S T E M S DANGER Defective or faulty electrical connections or unauthorized live components can lead to serious injuries or even death.
  • Page 8 M5 female threads! 2. Electrical connection Connect the FlexxPump 500 DLS to the external power supply or external controller (PLC) via the M12x1 interface using a suitable cable. Die FlexxPump 500 DLS is now switched on. 3. Check the assembly Make sure that the FlexxPump 500 DLS is properly and completely assembled.
  • Page 9 If this is the case, you can operate the FlexxPump 500 DLS. If this is not the case, change your PLC program accordingly. To use the FlexxPump 500 DLS, it first has to be properly mounted and installed. The installation is very simple and described in detail in chapter 6.2.
  • Page 10: Maintenance

    D I R E C T L U B R I C A T I O N S Y S T E M S Maintenance The following maintenance schedule must be observed for the FlexxPump 500 DLS: Maintenance Commis- After 500...
  • Page 11 S Y S T E M S 9.2 Oil-refill 1. Remove the housing from the power unit of the FlexxPump 500 DLS.  Separate the housing from the power unit by turning the retaining ring counterclock- wise.  Make sure that no dirt, water or foreign bodies enters the lubricant inlet.