Controller Settings; Technical Specifications - d&b audiotechnik V-SUB Manual

Table of Contents

Advertisement

V-SUB frequency response, standard and 100 Hz modes
d&b V-SUB Manual 1.5 en
AP setup
In connection with d&b ArrayProcessing (AP), the AP setup
contains the AP data that is generated by the d&b ArrayCalc
simulation software and transferred to the applicable amplifiers via
the d&b Remote network (OCA/AES70) using R1.
As soon as the data has been sent to the amplifiers, the AP setup is
automatically activated.

2.3.1 Controller settings

For acoustic adjustment the 100 Hz mode can be selected.
100 Hz mode
It can be used when V subwoofers are used to supplement V-TOP
cabinets operated in full range mode.
The 100 Hz mode can also be used to compensate for the effect
of close coupling between the subwoofer and V-TOP cabinets
operated in CUT mode.
With T-Series cabinets the standard mode is recommended.

2.4 Technical specifications

System data
Frequency response (–5 dB standard)
Frequency response (–5 dB 100 Hz mode)
Max. sound pressure (1 m, free field)
with D20/D12
with D80/D40
(SPLmax peak, pink noise test signal with crest factor of 4)
Loudspeaker data
Nominal impedance
Power handling capacity (RMS/peak 10 ms)
Components
Connections
Pin assignment
Weight
37 Hz - 115 Hz
37 Hz - 95 Hz
133 dB
137 dB
8 ohms
800/3200 W
1 x 18" driver
1 x 12" driver
NLT4 F/M
optional 2 x NL4 M or 2 x EP5
NLT4 F/M and NL4 M: 2+ / 2–
EP5: 3: + / 4: –
64 kg (141 lb)