Ariston HS C 24 FF NG Installation And Servicing page 54

Wall-hung gas boiler
Hide thumbs Also See for HS C 24 FF NG:
Table of Contents

Advertisement

INSTALLATION
Table of flue gas exhaust duct lengths
Type
C12
C32
Coaxial System
C42
B32
C12
C32
C42
Twin-pipe System
C52
C82
B22
S1 = Air intake S2 = Flue gas exhaust
Type of air suction/flue gas exhaust ducting
Combustion air drawn from the room
B22
Air drawn from the room
B32
Individual or shared flue gas
exhaust ducting built into the
building
Air drawn from the room
Combustion air intake from outside
C12
Flue gas exhaust and air
suction duct through external
wall in the same range of
pressure
C32
Flue gas exhaust
andair suction duct from
outsidewithroof terminalin the
same range of pressure
C42
Individual or shared flue
gas exhaust and air suction
through flue ducting built into
the building
54
/
Maximum Extension
HS C 24 FF NG
reduction ø 41
MIN
MAX
MIN
0,5
0,5
0,5/0,5
5/5
5/5
1,5
14
0,5
14
Exhaust-air (m)
reduction ø 44
without reduction
MAX
MIN
0,75
0,75
0,75
0,75
S1 = S2
13/13
13/13
S1 + S2
14
30
30
14
30
30
C52
Flue gas exhaust leading
outside and air suction duct
through external wall not in
the same range of pressure
C82
Flue gas exhaust through
individual or shared flue
ducting built into the building
Air suction through external
wall
Diameter of pipe
MAX
4
ø 60/100
4
20/20
ø 80/80
45
ø 80/80
45
ø 80