5-11 RECEIVE SENSITIVITY ADJUSTMENTS
1) Select an adjustment item (band) using [2] / [8].
2) Set the SSG as specifi ed (frequency, deviation and output level).
3) Push the [BAND] to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
ITEM
RECEIVE
NOTE:
SENSITIVITY
[30.1 MHz*]
[49.9 MHz*]
[50.1 MHz*]
[75.9 MHz*]
[76.1 MHz*]
[90.2 MHz*]
[117.9 MHz*]
[118.1 MHz*]
[146.1 MHz*]
[173.9 MHz*]
[174.1 MHz*]
[222.1 MHz*]
[259.9 MHz*]
[260.2 MHz*]
[305.2 MHz*]
[349.9 MHz*]
[350.1 MHz*]
[440.1 MHz*]
; This output level of a standard signal generator (SSG) is indicated as SSG's open circuit.
*; This frequency is an example only, and may differ from the actual frequency displayed on the function display.
All manuals and user guides at all-guides.com
"RECEIVE SENSITIVITY" must be adjusted before "S-METER." Otherwise, "S-METER" will
not be adjusted properly.
1 1) Set the power supply voltage to 7.4 V.
2) Connect an SSG to the antenna connector and set as;
Modulation
Deviation
2 • Set the SSG as;
Frequency
Level
3 • Set the SSG as;
Frequency
Level
4 • Set the SSG as;
Frequency
Level
5 • Set the SSG as;
Frequency
Level
6 • Set the SSG as;
Frequency
Level
7 • Set the SSG as;
Frequency
Level
8 • Set the SSG as;
Frequency
Level
9 • Set the SSG as;
Frequency
Level
10 • Set the SSG as;
[Tr]
Frequency
Level
11 • Set the SSG as;
Frequency
Level
12 • Set the SSG as;
Frequency
Level
13 • Set the SSG as;
Frequency
Level
14 • Set the SSG as;
Frequency
Level
15 • Set the SSG as;
Frequency
Level
16 • Set the SSG as;
Frequency
Level
17 • Set the SSG as;
Frequency
Level
18 • Set the SSG as;
Frequency
Level
19 • Set the SSG as;
Frequency
Level
OPERATION
: 1 kHz
: 3.5 kHz
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: –3 dBµ (–110 dBm)
: (Displayed on the function display)
: –3 dBµ (–110 dBm)
: (Displayed on the function display)
: –3 dBµ (–110 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: 0 dBµ (–107 dBm)
: (Displayed on the function display)
: –3 dBµ (–110 dBm)
: (Displayed on the function display)
: –3 dBµ (–110 dBm)
5 - 10
VALUE
Push
[BAND].
(Automatic
adjustment)