EPS PSB 10000 4U Operating Manual

Bidirectional dc power supply
Table of Contents

Advertisement

Quick Links

Operating Guide
PSB 10000 4U
Bidirectional DC Power Supply

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSB 10000 4U and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EPS PSB 10000 4U

  • Page 1 Operating Guide PSB 10000 4U Bidirectional DC Power Supply...
  • Page 2: Table Of Contents

    3.5.3 Configuration via the menu 2.1.3 Storage 3.5.4 Adjustment limits Unpacking and visual check 3.5.5 Changing the operating mode Installation 3.5.6 Manual adjustment of set values © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 3 The part of this document that deals with the handling of features on the control panel is only valid for devices with firmwares “KE: 3.02”. “HMI: 3.02” and “DR: 1.0.2.20” or higher. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 4 © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 5: General

    Symbol for general notices Warranty EPS Stromversorgung guarantees the functional competence of the applied technology and the stated performance param- eters. The warranty period begins with the delivery of free from defects equipment. Terms of guarantee are included in the general terms and conditions (TOS) of EPS Stromversorgung.
  • Page 6: Disposal Of Equipment

    Maximum current of the device in Ampere Maximum voltage of the device in Volt (“10080” = 80 V) Series: 10 = Series 10000 Type identification: PSB = Power Supply Bidirectional © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 7: Intended Usage

    Read and understand the operat- ing guide before using this device. Non-adherence of the instructions in the operating guide can result in serious injury or death. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 8: Safety

    (also see “3.5. Manual operation” and “3.5.3. Configuration via the menu” ) © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 9: Responsibility Of The Operator

    • before starting work must have read and understood the operating manual • © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 10: Alarm Signals

    Only if the current and voltage are supplied by the device as adjustable in the range of 0-100% FS, the device can be consid- ered as correctly operational. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 11: Technical Data

    1.8.2 General technical data Display: Color TFT touch screen with gorilla glass, 5”, 800pt x 480pt, capacitive Controls: 2 rotary knobs with pushbutton function, 1 pushbutton © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 12: Specific Technical Data

    0 - 10 V: ≤0.2%, 0 - 5 V: ≤0.4% *1 Models up to 80 V DC rating have reinforced insulation while all other models from 200 V DC rating have basic insulation © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 13 Enclosure: 19“ x 4U x 668 mm (26.3 in) Total: 19“ x 4U x min. 785 mm (31 in) Weight 50 kg (110 lb) Weight with water cooling 56 kg (126 lb) © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 14 +2000 V DC Article numbers Standard 30000803 30000804 30000805 30000809 Standard + Water Cooling 30000823 30000824 30000825 30000829 *1 At 100% power and 100% output voltage © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 15 +2000 V DC +2000 V DC Article numbers Standard 30000806 30000807 30000808 Standard + Water Cooling 30000826 30000827 30000828 *1 At 100% power and 100% output voltage © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 16: Views

    1.8.4 Views 1.8.4.1 Technical drawings PSB 10000 4U ≤200 V © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 17 6. AC input terminal 7. Grounding connection screw (PE) 8. Connector (DB15 female) for isolated analog programming, monitoring and other functions 9. USB interface 10. Ethernet interface © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 18 1.8.4.4 Technical drawings PSB 10000 4U ≥360 V © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 19 6. AC input terminal 7. Grounding connection screw (PE) 8. Connector (DB15 female) for isolated analog programming, monitoring and other functions 9. USB interface 10. Ethernet interface © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 20 7. AC input terminal 8. Grounding connection screw (PE) 9. Connector (DB15 female) for isolated analog programming, monitoring and other functions 10. USB interface 11. Ethernet interface © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 21: Control Elements

    DC terminal, no matter if the device is manually controlled or remotely. Port for USB sticks For the connection of standard USB sticks. See section “1.9.6.5. USB port (front side)” for more details. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 22: Construction And Function

    General description The power supplies of the PSB 10000 4U series are so-called bidirectional devices, incorporating the function of a laboratory power supply (source) and an electronic load (sink) into one unit. They allow for easy setup of applications according to the source-sink principle with a minimum of required hardware and cabling.
  • Page 23: Scope Of Delivery

    The two resistance set values are only displayed while resistance mode is active, while an actual resistance is only displayed during sink mode operation. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 24: The Control Panel (Hmi)

    (U), while the right knob can be switched by tapping on the depiction. Furthermore, the DC terminal status is indicated by two LEDs (green = on). There are following possible rotary know assignments: © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 25 Pushbutton function of the knobs The rotary knobs also have a pushbutton function which is used in all value adjustment to move the cursor by rotation like this: © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 26 File with log data recorded during normal operation in all modes. The file layout is identical to the those generated from the Logging feature in EPS Power Control. The <nr> field in the file name is automatically counted up if equally named files already exist in the folder.
  • Page 27: Usb Port (Rear Side)

    The modules can be installed by the user and hence retrofitted without problem. A firmware update of the device may be necessary in order to recognize and support certain modules. Switch your device off before adding or removing modules! © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 28: Analog Interface

    Reconfigu- ration on the Sense connectors is only permissible if the device is disconnected from AC supply and all DC sources! Figure 6- Remote sensing connectors © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 29: Master-Slave Bus

    The water taps are located on the rear side of the device, also see the rear view drawing in section 1.8.4 . Details about the connection, requirements and use of the water cooling can be found in section 2.3.4 . © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 30: Installation & Commissioning

    Continuous operation at the approved limit generates heat which must be removed, as well as voltage • loss which depends on cable length and heating. To compensate for these the cable cross section should be increased and the cable length reduced. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 31 When running a higher number of recovering, i. e. energy backfeeding units on the same leg of the installation, the total cur- rents per phase increases accordingly. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 32: Installing The Device

    The unacceptable positions, as shown below, are also valid for the vertical mount of the device onto a wall (room or inside a cabinet). The required air flow would be insufficient. Acceptable and unacceptable installation positions (air or water cooled, air cooled shown): Standing surface © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 33: Connection To Water Supply (Wc Models)

    23.3 24.22 26°C 13.15 14.84 16.26 17.67 18.9 20.09 21.29 22.32 23.32 24.31 25.16 27°C 14.08 15.68 17.24 18.57 19.83 21.11 22.23 23.31 24.32 25.22 26.1 © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 34 118.3 120.2 2.3.4.4 Notes The water flow should be started prior to powering the device, but at least prior to switching the DC terminal on • © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 35: Connection To Ac Supply

    Stripping length without cable end sleeve: 18-20 mm (0.75 in) • Valid for both, the ground conductor in the AC cable and the separate PE line for enclosure grounding © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 36 AC cable. It’s done be laying a separate protec- tive earth line (PE) of the same or higher cross section as in the AC cable and connected here. Figure 13 - Grounding point © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 37: Connection To Dc Loads Or Dc Sources

    M10 bolt on a metal rail M6 bolt on a metal rail Recommendation: ring lug with a 11 mm hole Recommendation: ring lug with a 6.5 mm hole © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 38: Grounding Of The Dc Terminal

    In case any DC pole is grounded, the operator of the device must reinstate the basic protection for human safety by installing appropriate external means, for instance a cover, everywhere the potential of the DC terminal is connected to. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 39: Connection Of Remote Sensing

    Dangerous voltage on the sense connectors! The sense cover must always be installed. Figure 14 - Example for remote sensing wiring (DC terminal and Sense terminal covers left way for illustrative purposes) Allowed connection schemes: © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 40: Installation Of An Interface Module

    On the bottom side of the module are two plas- tic nibs which must click into the green board (PCB) so that the module is properly aligned on the rear wall of the device. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 41: Connection Of The Analog Interface

    Refer to “2.3.13. Initial commission” . Only after successful checking of the device as listed may it be operated as usual. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 42: Terms

    Setting Slow will result in a higher transient time and higher voltage drop, but less overshooting, while Fast is vice versa. Also see “3.3.7. Dynamic characteristics and stability criteria” and “3.5.3.1. Sub menu “Settings”” . © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 43: Current Regulation / Constant Current / Current Limiting

    1-2% of the rated voltage (on top of the voltage setting), while the duration mainly depends on the charging state of the capacities on the DC output and also the capacity value. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 44: Power Regulation / Constant Power / Power Limiting

    With resistance mode being activated the function generator will be unavailable and the actual power value provided by the device does not include the simulated power dissipation of Ri. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 45: Resistance Regulation / Constant Resistance (Sink Mode)

    We recommend: 10/60/80 V models: 1000uF..4700uF 200/360 V models: 100uF...470uF 500 V models: 47uF...150uF 750/920/1000 V models: 22uF...100uF 1500/2000 V models: 4.7uF...22uF © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 46: Alarm Conditions

    This function serves to protect the connected load application (source mode) or the external source (sink mode) so it’s not overloaded and possibly damaged due to an excessive power. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 47: Safety Ovp

    This alarm has to be acknowledged after the cause has been removed. Should the device neither be master nor slave, the Share bus cable should be removed for unimpeded operation. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 48: Manual Operation

    Many settings are self-explanatory, others are not. Those will be ex- plained on the pages following. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 49 = Levels and function as described in the table in 3.6.4.3 • Inverted = Levels and function will be inverted • Also see “3.6.4.7. Application examples” © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 50 -100%...0...100% whereas 0% is put in the center of the analog signal range, it means either at 5 V or 2.5 V. Each of both actual values only has half resolution. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 51 © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 52 There are furthermore adjustable communication timeouts. For more information about these timeout refer to the external, on USB stick included documentation “Programming guide ModBus & SCPI”. The USB itself doesn’t require any settings. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 53 String input box for a user-definable text which describes the Profibus slave. Max. length: 54 characters Station Name String input box for a user-definable text which describes the Profinet station name. Max. length: 200 characters © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 54 The baud rate is selectable, other serial settings can’t be changed and are defined like this: 8 data bits, 1 stop bit, parity = none Baud rates: 2400Bd, 4800Bd, 9600Bd, 19200Bd, 38400Bd, 57600Bd, 115200Bd © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 55 ModBus RTU or ModBus TCP format which fully comply to the specification and are compatible to softwares available on the market. With Limited the device would still use the old, partially wrong message format (see programming guide for details). © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 56 Furthermore, the backlight intensity can be adjusted here. Lock See “3.8. Locking the control panel (HMI)” and “3.9. Locking the adjustment limits and user pro- files” © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 57: Adjustment Limits

    The actual operating mode, which is only indicated while the DC terminal is switched on, solely depends only on the set val- ues. For more information see section “3.3. Operating modes”. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 58: Manual Adjustment Of Set Values

    Upon entering a value which exceeds the corresponding limit, a note would pop up, the value in the frame reset to 0 and not be accepted and submitted. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 59: Switching The Dc Terminal On Or Off

    The logging stores files of CSV format on the stick where the layout of the log data is the same as when logging via PC with software EPS Power Control. The advantage of USB logging over PC logging is the mobility and that no PC is required. The logging feature just has to be activated and configured in the Settings.
  • Page 60: The Quick Menu

    The device offers a quick menu which allows for the quick access to often used features and modes being switched on or off in the “Settings” menu. It can be opened by swiping up from the bottom screen edge or tapping the bar: Overview: © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 61: The Graph

    Swiping on the three scales (Y axis) moves them up or down • • Tapping the menu touch area ( ) exits the graph screen anytime © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 62: Remote Control

    Programming details for the rear interfaces, the communication protocols etc. are to be found in the documentation “Pro- gramming Guide ModBus & SCPI“ which is supplied on the included USB stick or which is available as download from the manufacturer’s website. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 63 The timeout of the monitoring can be changed anytime via remote control; the new value would only be valid after the • current timeout has elapsed The interface monitoring doesn’t deactivate the Ethernet connection timeout (see 3.5.3.6 ), so these two timeouts can overlap • © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 64: Remote Control Via The Analog Interface

    PF and OVP being signaled at the same time, so it would require to select the alarm indication on pin 6 to at least signal PF and for pin 14 to signal OVP in any of the combinations. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 65 10 V range. In the 5 V range this resolution halves. Due to tolerances, the truly achievable resolu- tion can be slightly lower. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 66 -> “REM-SB level” being set to “Normal”, it requests to switch the DC terminal on. So when activating remote control, the DC terminal will instantly switch on. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 67 Reading actual values The AI provides the DC terminal values as current and voltage monitor. These can be read using a standard multimeter or similar. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 68 DC current • is flowing in any of both directions, one of the pins will indicate with a level > 0 V. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 69: Alarms And Monitoring

    Triggers an alarm as soon as the output or input pow- Display, analog & Protection er reaches the defined threshold. The DC terminal will be 0 W...1.1*P digital interfaces switched off. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 70 Swipe with your finger up from the bottom edge of the screen or directly tap on the bottom bar: The quick menu will open. Tap on to activate the alarm sound, or on to deactivate it. Leave the quick menu. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 71 User events are part of the currently selected user profile. Thus, if another user profile or the default profile is loaded, the events could either be differently configured or not at all. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 72: Locking The Control Panel (Hmi)

    In the group tap on “Unlock limits and profiles”. You will be requested to enter the 4-digit PIN. Deactivate the lock by entering the correct PIN. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 73: Loading And Saving User Profiles

    Loading a user profile works the same way, but in the requester you would then tap Load under Load profile?. Alternatively, you may import the profile or export it as file to a USB stick with Import/Export. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 74: The Function Generator

    DC terminal in order to decrease rise and fall times. This extra load has a positive impact on periodic functions like rectangle or sine wave. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 75: Method Of Operation

    It’s recommended to carefully configure them so the MS system can work as expected and the slaves wouldn’t impact the function run in a negative way. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 76: Manual Operation

    Any device alarm (power fail, overtemperature etc.), protection (OPP, OCP) or event with Action = Alarm stops the function progress automatically, switches off the DC terminal and reports the alarm. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 77: Sine Wave Function

    0.1 ms...36,000,000 ms Rising edge time Δt of the triangular wave signal Time t2 0.1 ms...36,000,000 ms Falling edge time Δt of the triangular wave signal © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 78: Rectangular Function

    The sum of t1 and t2, the period, is 1/25 Hz = 40 ms. For a duty cycle of 80% the pulse time (t1) is 40 ms*0.8 = 32 ms and the pause time (t2) is 8 ms © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 79: Trapezoidal Function

    I/P (EL) 0...I Set values of current and power for sink mode. If either I=0 or P=0, the device would only work in source mode © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 80: Arbitrary Function

    Start sequence...99 Last sequence point in the block After continuing with there are global set values to define as last part of the function generator setup. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 81 This impacts the period of the sine waves such that each new wave will be shorter over the total span of the sequence time. f (start) f (end) Seq.time © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 82 Point 1 Point 2 © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 83 The file naming, however, is unique. A filter prevents you from loading a WAVE_I file after you have selected Arbitrary --> U in the function generator menu. The file would not be listed at all. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 84: Ramp Function

    10 h after reaching the ramp end, the function will stop automatically (i.e. I = 0 A, in case the ramp was assigned to the current), unless it has been stopped manually before. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 85: Iu Table Function (Xy Table)

    If these specifications are not met, the device won’t accept the file and put out an error message in the display. The USB stick may contain multiple IU files with different names and list them for the selection of one. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 86: Simple Pv (Photovoltaics) Function

    Short-circuit current at max. load and low voltage Umpp 0 V...Uoc DC output voltage of the MPP Impp 0 A...Isc DC output current of the MPP © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 87 MPP or not. Stop the function run anytime by the stop button or by switching off the DC output. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 88: Fc Table Function (Fuel Cell)

    After setting up everything proceed to the main function generator screen with . After the function has been loaded to the internal XY generator, the simulation is ready to start. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 89: Extended Pv Function According To En 50530

    PV curve. Evaluation of a solar inverter, as described in the norm paper, is only possible with our software EPS Power Control. It will, amongst other result data, determine the inverter’s efficiency. The impact of the parameters on the PV curve and the simulation is described in the norm paper of EN 50530, which users can refer to in case more detailed description is required.
  • Page 90 For example, an american Excel should by default use the dot as decimal separator and the comma as column separator, which would match the selection “USB file separator format = US”. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 91 Pactual = Actual power on the DC output Umpp / Impp / Pmpp = Voltage, current and power in the MPP of the currently calculated PV curve © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 92 Step 3: Select simulation mode For a description of the available simulation modes see 3.11.15.4 . When selecting the configuration continues with Step 4, otherwise an additional step is required © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 93 The data can later be used to visualize, analyze and determine characteristics of the simulated solar panel and also of the solar inverter which is usually used as load when running such tests. More details can be found in the standard paper. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 94 When reading the PV table, you will receive up to 4096 current values. The table data could be visualized in an XY diagram in tools like Excel. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 95: Battery Test Function

    This form of test flow is available on the HMI as well as in EPS Power Control (license based extra which isn’t free of charge), but not in digital or analog remote control.
  • Page 96 Discharge end voltage 0...U Threshold (in Volt) to stop discharging (only for discharge modes) Action: Ah limit None, Signal, End of Enables the optional stop condition test © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 97 Any device alarm which would also switch off the DC input, like OT • Reaching the threshold U (discharge end voltage) • Reaching the threshold for charging end current • © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 98: Mpp Tracking Function

    Delta P was set to a quite small value, so the power curve looks almost linear. With a small Delta P the load would always track close to the MPP. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 99 The decimal separator of broken values must follow the setting “Log file separator format” where selection means dot • as decimal separator and selection Standard means comma © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 100: Remote Control Of The Function Generator

    REM-SB switching the DC terminal off and on, which will also stop and restart the function • The function generator is unavailable if R mode (resistance) is activated © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 101: Other Applications

    © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 102 Device position Termination setting(s) Master (at end of bus) BIAS + TERM Master (central in bus) BIAS Slave (at end of bus) TERM Slave (central in bus) © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 103 As long as MS mode remains activated, the initialization process of the master-slave system will be re- peated each time the master unit is powered. The initialization can also be repeated manually anytime via the Settings menu, in group “Master-Slave”. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 104 OCP alarm though the global OCP limit of the MS system was not reached. The same can occur with the OPP alarm. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 105: Series Connection

    SEMI F47 it’s delayed for at least 2 seconds or will never occur. In this case, the device wouldn’t show any reaction to the sag, nor register the occurrence in any form. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 106: Service And Maintenance

    The firmware of the control panel (HMI), of the communication unit (KE) and the digital controller (DR), if necessary, is updat- ed via the rear side USB port. For this the software EPS Power Control is needed which is included with the device or available as download from our website together with the firmware update, or upon request.
  • Page 107: Trouble-Shooting Device Problems

    As an additional measure include fuses in line with the DC cables which could attenuate or even prevent damage to the device. © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...
  • Page 108 Headquarter eMail addresses Telephone EPS Stromversorgung GmbH All topics: Switchboard: +49 821 / 570451-0 Alter Postweg 101 info@eps-germany.de 86159 Augsburg Germany © EPS Stromversorgung in 2022, this information is subject to change without notice 30000800_manual_psb_10000_4u_30kw_en_04...