Figure 4: Model 4100 Cover Plate - Top View; Figure 5: Model 4150 Cover Plate - Top View; Figure 6: Cover Plate - End View - Geokon 4100 Series Instruction Manual

Vibrating wire strain gauges
Table of Contents

Advertisement

FIGURE 4: Model 4100 Cover Plate - Top View

FIGURE 5: Model 4150 Cover Plate - Top View

FIGURE 6: Cover Plate - End View

INSTALL THE COVER PLATES AS FOLLOWS:
1.
Weld the two 9.5 x 51 mm (3/8 x 2") long hex bolts in place head down. The
bolts should be spaced at a nominal 530 mm (21") apart. A spacer jig is
available from
GEOKON
the holes in the cover plate can be used to mark the bolt locations. One hole
in the cover plate is slotted, so the spacing is not critical. Avoid welding
anywhere near the gauge as this will cause large local distortions in the
metal. Use either a special stud welder or an arc welder to weld the head of
the bolt to the surface.
MODEL 4100/4150 SERIES VIBRATING WIRE STRAIN GAUGES | INSTRUMENT PROTECTION | 5
, or the cover plate can be flipped onto its back and
4:
5:
6:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4150 series41514150-54100-84150-44100-9

Table of Contents