WARRANTY STATEMENT warrants its products to be free of defects in materials and workmanship, GEOKON under normal use and service for a period of 13 months from date of purchase. If the unit should malfunction, it must be returned to the factory for evaluation, freight prepaid.
Page 5
FIGURES FIGURE 1: DETACH THE 20 MM END PIECE USING VICE GRIPS ........1 FIGURE 2: SLIDE THE SWAGELOK NUT AND FERRULES ONTO THE SHEATHING ..2 FIGURE 3: MELT THE SOLDER AND ADHERE THE WIRES TOGETHER ......2 FIGURE 4: HEAT SHRINK TUBING SECURELY BONDED TO THE WIRES ......3 FIGURE 5: TWIST AND COIL THE WIRES TO SIMPLIFY INSERTING THE SPLICE ....
Page 7
20 mm piece back and forth until it separates from the main section. Discard this piece and ensure there are no nicks in the sheathing of the internal wiring. FIGURE 1: Detach the 20 mm end piece using vice grips GEOKON | 4500HT SENSOR CONNECTION PROCEDURE | 1...
Page 8
Apply enough heat to the overlapped wires to melt the solder and adhere the wires together. FIGURE 3: Melt the solder and adhere the wires together 2 | 4500HT SENSOR CONNECTION PROCEDURE | GEOKON...
Page 9
12 mm wrenches (see Figure 6). NOTE: If the ferrule of the 4 mm Swagelok is already crimped on the tube, the nut needs to be only slightly tightened with a wrench. GEOKON | 4500HT SENSOR CONNECTION PROCEDURE | 3...
Page 10
FIGURE 6: Tighten the Swagelok Perform continuity and short-circuit checks to verify that the splice was successful. 4 | 4500HT SENSOR CONNECTION PROCEDURE | GEOKON...
Page 12
GEOKON Phone: +1 (603) 448-1562 GEOKON 48 Spencer Street Email: info@geokon.com is an ISO 9001:2015 Lebanon, New Hampshire Website: www.geokon.com registered company 03766, USA...