No.
Parts
3
Assy
Control Out
4
Heat Exchanger
38
SAMSUNG ELECTRONICS
Procedure
1) To remove the Cover control box : Pull
the motor wire is allow sufficient space
as shown on the right side and then
remove the screw.
2) Detach several connectors from the
Assy Control Out.
3) Detach several connectors from the
PCB of Assy Control Out.
1) Release the refrigerant at first.
2) Loosen ng screw on both sides.
3) Disassemble the pipes in both
inlet and outlet with welding torch.
4) Detach the Heat Exchanger.
Remark