Page 1
EN - Installation, use and maintenance manual A8 V / C ROUND STEEL / TOP / COAX A10 V / C ROUND STEEL / TOP / COAX...
Page 2
Dear Customer. Thank you for choosing a product from our range. You are invited to read this manual carefully before using it, to take full advantage of all its features, in complete safety. This manual contains information necessary for correct installation, start-up, use, cleaning and maintenance of the product.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” Ambient temperature setting MANUAL INDEX Fireplace power setting 1 Introduction Switching on the product Symbols Planned use 9 The working phase Improper use 9.1 Saving mode Importance of the manual 9.2 Air conditioning comfort function...
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” INTRODUCTION 1.3 IMPROPER USE The product by Nobis was designed and manufactured The product must be intended for the use for which it in compliance with the reference standards for the was expressly designed;...
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” • The product can be used by children over • all parts resulting as being faulty due to 8 years of age and people with reduced...
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” CHARACTERISTICS OF THE PELLETS SPARE PARTS Wood pellets are fuel made of pressed sawdust, of- Only use original spare parts. ten recovered from carpentry processing waste. The...
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” The air intake is not necessary for INSTALLATION installation of the hermetic appliances that take air directly from outside. Check and All local and national legislation and European...
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” 3.3 CHIMNEY FLUE 3.5 HERMETIC PRODUCT INSTALLATION When installing the chimney flue, the following provi- In the event of installation of a hermetic product, sions must be applied.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” 3.6 EXAMPLES OF CORRECT INSTALLATION installation of the product (A) necessary for the hori- zontal section for connection to an existing chimney flue. Based on a slope of 3-5%, to reduce ash deposit in the horizontal pipe section which must not be over 3m (1).
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” To remove the 3.7 DOCUMENTATION TO ISSUE appliance from the When installation is concluded, the installation tech- pallet, you can remove nician must deliver to the user: the two screws placed •...
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” SIDE PANEL ASSEMBLY Position the stove canalization adapter by means of the 2 screws 5, present in the kit, and an 8mm hexa- Remove the right-hand side panel from its packa- gonal wrench.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” When finished, reposition the cast iron top. It is compulsory for the system to be grounded and have a differential switch in compliance with legis- lation in force.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” Revisioni Revisioni Area Rev. Descrizione Data Approvata Area Rev. Descrizione Data Approvata Revisioni RILASCIO PROGETTO 03/04/2020 R.A. Area Rev. Descrizione Data Approvata RILASCIO PROGETTO 03/04/2020 R.A.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” USER INTERFACE DESCRIPTION 6.2 DESCRIPTION OF THE CONTROL KEYS Once all the installation, covering assembly (where The screen looks like this: present as a kit) and electrical connection are in place, with utmost attention, access the rear part of the product to power it.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” NAVIGATION MENU FIRST START-UP INSTRUCTIONS To access the menu and display all entries available, This chapter highlights a series of operations to carry press key on the stand-by screen, out during the first start-up phase of the appliance.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” 8.2 MENU 01 - HOUR-DATE SETTINGS Below you can find the procedure to set date and time on the models of the manufacturer’s range, useful for the timer thermostat.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” 8.6 POWER SETTINGS 8.4 MENU 04 - AUTO FUNCTION The logic, relating to this type of management, is as The fireplace power defines the quantity of heat pro- follows: duced by the appliance.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” When COMFORT CLIMA (function included in SAVING Always vacuum the brazier using an ash cleaner. MODE) is active, it also ensures - if the house has a good FIRE HAZARD.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” OPERATIONAL PROCEDURE: STATUS SCREEN. To recognize when the appliance is about to switch MENU 02 >> TIMER off in COMFORT CLIMA mode, the following screen...
Page 20
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” The number, expressed in seconds, indicates the auger OPERATIONAL PROCEDURE: rotation time during loading phase. MENU 06 >> P/A RATIO After this, the auger stops automatically and the appliance can switch on.
Page 21
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” 10.4 MENU 12 - STOVE STATUS 10.6 MENU 09 - FIRMWARE VERSION This function allows you to verify that the most impor- To view the version of the firmware installed for...
Page 22
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” Activate/Deactivate the function with 11.1 SINGLE CANALIZATION SETTINGS and confirm by pressing This section will explain how to both enable/disable Press several times to return to the STAND-BY and set manually the ventilation speed assigned to screen.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” If you want to manage the temperature of the room 11.3 DISPLAY CANALIZATION STATUS to be channeled after activating the function de- To view the status of the channeling, from the STAND...
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” If the PS function is not configured, the fan will always remain independent of the power of the product. Confirm your change by pressing and proceed to the next setting.
Page 25
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” 12 PHASES CONCISE DIAGRAM 13 FUNCTIONS CONCISE DIAGRAM PHASE DESCRIPTION PHASE DESCRIPTION Ambient setting in MAN - The phase starts to pre-heat the re...
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” DESCRIPTION OF ALARMS ANOMALIES CONCISE DIAGRAM Each alarm condition causes the appliance to PHASE DESCRIPTION immediately switch off. Press the switch on key P3 The appliance signals a malfunc- to reset the alarm.
Page 27
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” ALARM CODE REASON ALARM CODE REASON The rotations of the smoke extractor show a The cleaner has not completed movement and is not found in the...
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” 17 CLEANING THE APPLIANCE ALARM CODE REASON During the pellet loading phase of Product installation must take place in in such a the product, the tank door was not closed way as to ensure easy access to the appliance properly.
Page 29
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” Lift the “cold lever”, supplied with the product, With a soft bristle brush, eliminate the to release the door and allow combustion particulate, allowing it to fall in the slide fire door opening, as in the figure below: beneath.
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” OPERATING PROCEDURE: 17.2 CLEANING THE GLASS DOOR Open the door positioned under the fire door, as in To clean the glass, use a cotton cloth the figure below: or kitchen paper.
Page 31
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” CLEANING CYCLES TABLE Below, the control and/or maintenance intervention are summarised which are indispensable for correct appliance operation. PARTS/FREQUENCY TIME 7 DD Ash pan (approx. time)
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” 18 WIRING DIAGRAM R/RH R/RH LEGEND: SAFETY REMOTE UNIT SELECTION PRESSURE SENSOR SMOKE EXTRACTOR VACUUM SWITCH STROKE COUNTER UPGRADE FW KEY VENTILATION MANUAL RESET THERMAL...
Page 33
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” MAINTENANCE DATE INTERVENTION CARRIED OUT...
Page 34
ENGLISH Use and Maintenance Manual model “A8 - A10 V/C ROUND STEEL / TOP / COAX” NOTE...
Page 36
NOBIS srl Via Aldo Kupfer N.31 25036 - Palazzolo s/O - BS www.nobisfire.it Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products without prior warning.