I/O data exchange is only actually active when parameter 4014 "Fieldbus state"
is set to "Operational". In all other cases, the master has not started to exchange
I/O data with the EXP-ETH-GD-ADV200 card. This could be due to incorrect as-
sembly instance configuration, for example if the size set on the master is not the
same as that obtained from the settings in the "Fieldbus M2S" and "Fieldbus S2M"
menus, or if the master is not in the "Run" state.
If parameter 4014 "Fieldbus state" is "Operational" the I/O data are updated with
the programmed parameter values. The drive can only be enabled in this state.
2.2.2.

Writing Output data

2.2.2.1.

Fieldbus M2S Menu

Wdecomp is used to configure the control word. The Wdecomp configuration on
the first M -> S word ("Export" mode) is shown below:
Now simply connect the single Wdecomp bits. For Commands the drive must be
set to "Remote" and "Digital" mode, as explained in the ADV200 manual.