INSTALLATION OF INDOOR UNIT

Let pipe go through the wall hole and attach
the indoor unit to the mounting plate.
(Locate the rib of the indoor unit in the hole of
the mounting plate.)
THE CONNECTION OF PIPE
The number of bends in the pipe of the indoor
unit should not exceed 10. The number of bends
in the pipe of the indoor unit and outdoor unit
should not exceed 15.
The radius of bends should be more than 10cm.
A layer of air proof oil should be coated on the
joint before the pipe has been connected. Align
the axis of each pipe and tighten screw nut with
a spanner (see the right diagram).
����
������ ����
��� ����
��� ����
ARRANGEMENT OF DRAIN HOSE
To eject the condensated water easily, the drain hose should be positioned downward.
The arrangement in diagrams 2-5 are wrong.
• If the drain hose connected with the indoor
unit is short, it may be extended by the hose
in the accessory box.
• When the drain hose must be run through
the house, it should be wrapped by the
special heat insulated materials.
SEALING OF WALL HOLE AND FASTENING
OF PIPE
• Use putty to seal the wall hole.
• Use clamp (pipe fastener) to secure the pipe
at specifi ed position.
�������� �� ����
������ ������
������ ������
������ ������