OUTDOOR UNIT

OUTDOOR UNIT
��������
��� ���������� ������ ���� �� ������� ���������
������� ����� ���� �� ���� �� ������� ������ ���� ��� ������� ����� ������ ���� ���
����� ��� ����� ������� �� ���� �� ���������
�� ���������� ������� ���� ������ ��������� ��� ������ ��������� ������������

CONNECTING PIPE WORK

CONNECTING PIPE WORK
1. NOTE:
• The drain must be arranged beneath the
copper pipe.
• The drain hose must not be hunched or bent.
• When the drain hose runs through the house,
it should be wrapped with special heat
insulated materials.
• The copper pipe and the drain hose must be
wrapped by felt strip. Heat insulated pad should
be used in the place that the pipe contacts the
wall.
2. ROUTE OF PIPE:
• If pipe came out of the right side of the indoor
unit, cut part "1" on the unit.
• If pipe came out of the lower-right side of the
indoor unit, cut part "2" on the unit.
• If pipe came out of the left side of the indoor
unit, cut part "3" on the unit.
3. REFIT OF DRAIN HOSE
• If pipe comes out of the left side of the indoor
unit, the drain hose must be refi tted otherwise
water leakage may occur.
• Refi t methods: Interchange the position of
drain hose and drain rubber bib, the right
diagram is normal position.
��������
���� ������������� ��� ������ ��� ����� ���� ���� ������ �� ������� ��� ���
��������� ��������� ����� ����� �� � ���� �� �������� ������
• Clearance is not possible after refi tting as it
leads to water leakage.
17
�� �� ����������