STIEBEL ELTRON XG 35 EC Operation And Installation Instructions Manual

STIEBEL ELTRON XG 35 EC Operation And Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

XG 35 EC / 45 EC
English
Instantaneous shower water heater - Operation and installation instructions
ไทย
คู ่ ม ื อ แนะนำ � ก�รใช้ ง �นและติ ด ตั ้ ง เครื่ อ งทำ � น้ ำ � อุ ่ น
This shower water heater must be installed (water and electrical installation),
commissioned and serviced by approved service technicians in
accordance with these instructions.
เครื่ อ งทำ � น้ ำ � อุ ่ น นี ้ จ ะต้ อ งทำ � ก�รติ ด ตั ้ ง ต�มวิ ธ ี ก �รในคู ่ ม ื อ โดยช่ � งผู ้ ช ำ � น�ญง�นเท่ � นั ้ น

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XG 35 EC and is the answer not in the manual?

Questions and answers

Summary of Contents for STIEBEL ELTRON XG 35 EC

  • Page 1 XG 35 EC / 45 EC English Instantaneous shower water heater - Operation and installation instructions ไทย คู ่ ม ื อ แนะนำ � ก�รใช้ ง �นและติ ด ตั ้ ง เครื่ อ งทำ � น้ ำ � อุ ่ น...
  • Page 2 เครื่ อ งทำ � น้ ำ � อุ ่ น หรื อ น้ ำ � ร้ อ นนี ้ โ ดยไม่ ไ ด้ ร ั บ Cleaning and user ก�รควบคุ ม ดู แ ล maintenance shall not be made by children without supervision. STIEBEL ELTRON...
  • Page 3: Table Of Contents

    2.11 ส�ระสำ � คั ญ ด้ � นง�นบริ ก �ร ........................ 28 3. ก�รรั บ ประกั น ............................. 29 4. ก�รแก้ ไ ขข้ อ ขั ด ข้ อ ง สำ � หรั บ ผู ้ ใ ช้ ง �น ..................... 29 STIEBEL ELTRON...
  • Page 4: Installation Instruction

    Fig 1 Fig 3 Wall Mounting Wiring diagram Flow SW. A - Heating Element B - XG-PC Front PCB C - ELCB D - XG-PC Control PCB E - Thermal Cut-Out 220-240 VAC. ONLY Fig 2 Fig 4 STIEBEL ELTRON...
  • Page 5: Detailed Description

    7. Terminal block for earth wire 16. Filter 8. ELCB 17. Rubber seal 9. Connector to PCB control 18. Water Valve (Base) 19. Power Light 10. Reed switch 20. Connector to PCB Control (Cover) Cover Base Pic 8 Fig 5 STIEBEL ELTRON...
  • Page 6: Installing The Unit

    - Release cover securing screw. Fig 6 Fig 8 - Feed the connection cable seal - Open and remove cover. in the rear wall. Fig 7 Fig 9 STIEBEL ELTRON...
  • Page 7 - Guide the unit over the wall securing screws and slide it downwards. N wire Fig 12 Fig 10 - Fit a secure connection cable (See recommended cable size in ensure dimensions are correct. technical data table) L wire Earth wire Fig 11 Fig 13 STIEBEL ELTRON...
  • Page 8 - Straighten the unit and tighten the screws. Fig 16 Fig 14 - Connect the electrical supply - Fit the cover and secure with from cover into the PCB control. the screw. Fig 15 Fig 17 STIEBEL ELTRON...
  • Page 9 - Fit the cold water pipe thoroughly position. (Fig 5 number 18). Fig 20 Fig 18 - Fit the filter and silicone gasket - Fit the shower accessories to (Fig 5 number 16, 17). the unit. Fig 19 Fig 21 STIEBEL ELTRON...
  • Page 10: Operation Instruction

    2.1 Description of the unit. This appliance is designed for domestic The STIEBEL ELTRON XG is a slim and use. It can be used safely by untrained pressureless instantaneous water heater persons. The appliance can also be...
  • Page 11: The Essentials - In Brief

    2.2 The essentials - in brief a. Water valve b. Rotary control for temperature adjustment c. “Power” light d. Shower accessories Shower head level must not be higher than the unit. Fig 22 STIEBEL ELTRON...
  • Page 12: Important Information (Elcb)

    ELCB once a month. 2.3.2. The unit is equipped with a Before using this unit, switch on the Double action thermostat. electrical supply then press the Reset Button (E). Incase of permanent thermostat cut off, contact Stiebel services. Push Fig 23 STIEBEL ELTRON...
  • Page 13: Pre-Operation

    If, during a shower , the depends on the power of the unit, the cold water temperature and the flow volume. STIEBEL ELTRON...
  • Page 14: Technical Data

    4.9 - 21.3 240 V 4.2 - 17.5 5.4 - 22.5 Note: The cable sizes can only be a guiding value. Always abide by the corresponding local standards, laws and regulations. Stiebel Eltron cannot be held liable for any damages. STIEBEL ELTRON...
  • Page 15: Regulations And Provisions

    Stiebel Eltron installer. The device must be capable of - Hand over this instruction manual being isolated from the mains, to the user and to be kept on a safe for example by fuses, with an isolating place for future reference.
  • Page 16: Guarantee

    - The shower head is - Clean shower head blocked with dirt or or remove limescale. limescale. - ELCB activated. - Press ELCB Reset button. STIEBEL ELTRON...
  • Page 17: คู ่ ม ื อ แนะนำ � ก�รติ ด ตั ้ ง

    ก�รติ ด ตั ้ ง บนผนั ง วงจรไฟฟ้ � Flow SW. A - Heating Element B - XG-PC Front PCB C - ELCB D - XG-PC Control PCB E - Thermal Cut-Out 220-240 VAC. ONLY ภ�พที ่ 2 ภ�พที ่ 4 STIEBEL ELTRON...
  • Page 18: ส่ ว นประกอบของเครื่ อ ง

    9. ปลั ๊ ก ต่ อ แผงวงจรควบคุ ม (ตั ว เครื่ อ ง) 20. ปลั ๊ ก ต่ อ แผงวงจรควบคุ ม (ฝ�ครอบเครื่ อ ง) 10. สวิ ต ซ์ แ รงดั น น้ ำ � Reed switch ฝ�ครอบเครื่ อ ง ตั ว เครื่ อ ง Pic 8 ภ�พที ่ 5 STIEBEL ELTRON...
  • Page 19: ก�รติ ด ตั ้ ง

    - เปิ ด ฝ�ครอบเครื่ อ งออก - สอดส�ยไฟทะลุ ผ ่ � นซี ล ย�งด้ � นหลั ง ต้ อ งแน่ ใ จ ว่ � ได้ ต ั ด กระแสไฟฟ้ � จ�กเมนหลั ก แล้ ว ภ�พที ่ 7 ภ�พที ่ 9 STIEBEL ELTRON...
  • Page 20 - (ดู ข น�ดส�ยไฟที ่ ใ ช้ ท ี ่ ข ้ อ มู ล ท�งเทคนิ ค ) ยึ ด ส�ยไฟให้ แ น่ น ให้ แ น่ ใ จว่ � ใช้ ข น�ดส�ยไฟถู ก ต้ อ ง L wire Earth wire ภ�พที ่ 11 ภ�พที ่ 13 STIEBEL ELTRON...
  • Page 21 - นำ � ส�ยไฟเชื่ อ มต่ อ กั น ระหว่ � งแผงวงจรบนฝ� - ปิ ด ฝ�ครอบเครื่ อ ง และยึ ด สกรู ครอบเครื่ อ ง และแผงวงจรที ่ ต ั ว เครื่ อ ง ภ�พที ่ 15 ภ�พที ่ 17 STIEBEL ELTRON...
  • Page 22 - ใส่ ต ะแกรงกรองตะกอน และ ซี ล ย�ง - ต่ อ ข้ อ ต่ อ ที ่ ท �งน้ ำ � ออกและหั ว ฝั ก บั ว พร้ อ มซี ล (ภ�พ 5 หม�ยเลข 16,17) ย�งต่ อ ไป ภ�พที ่ 19 ภ�พที ่ 21 STIEBEL ELTRON...
  • Page 23: คู ่ ม ื อ แนะนำ � ในก�รใช้ ง �น

    เด็ ก เล่ น เครื่ อ งทำ � น้ ำ � อุ ่ น นี ้ หรื อ ทำ � คว�มสะอ�ดใด ๆ หรื อ กระทำ � ก�รใด ๆ โดยไม่ อ ยู ่ ภ �ยใต้ ก �รดู แ ลจ�ก ผู ้ ใ หญ่ STIEBEL ELTRON...
  • Page 24: ส่ ว นประกอบที ่ ส ำ � คั ญ ในก�รใช้ ง �นภ�ยนอก

    ปุ ่ ม หมุ น สำ � หรั บ ปรั บ อุ ณ หภู ม ิ c. ไฟแสดงก�รทำ � ง�น d. อุ ป กรณ์ ฝ ั ก บั ว หั ว ฝั ก บั ว ไม่ ค วรอยู ่ ส ู ง กว่ � ตั ว เครื่ อ ง ภ�พที ่ 22 STIEBEL ELTRON...
  • Page 25: ข้ อ มู ล สำ � คั ญ และระบบคว�มปลอดภั ย (Elcb)

    โดยอั ต โนมั ต ิ ใ หม่ ) ให้ ห ยุ ด ก�รใช้ ง �นและติ ด ต่ อ ศู น ย์ บ ริ ก �รของ สตี เ บล เอลทรอน เพื่ อ ทำ � ก�ร ตรวจเช็ ค และซ่ อ ม Push ภ�พที ่ 23 STIEBEL ELTRON...
  • Page 26: ก�รใช้ ง �นครั ้ ง แรก

    อุ ณ หภู ม ิ น ้ ำ � ร้ อ นขึ ้ น อยู ่ ก ั บ กำ � ลั ง ไฟของเครื่ อ ง อุ ณ หภู ม ิ น ้ ำ � เข้ � และปริ ม �ณน้ ำ � ไหลเข้ � STIEBEL ELTRON...
  • Page 27: ข้ อ มู ล ท�งเทคนิ ค

    2. คู ่ ม ื อ แนะนำ � ก�รติ ด ตั ้ ง สำ � หรั บ ผู ้ ใ ช้ และช่ � งผู ้ ช ำ � น�ญง�น 2.8 ข้ อ มู ล ท�งเทคนิ ค รุ ่ น XG 35 EC XG 45 EC คว�มจุ แ ทงค์ ลิ ต ร...
  • Page 28: กฎข้ อ บั ง คั บ

    ไฟฟ้ � รั ่ ว , เครื่ อ งไหม้ และปั ญ ห�อื่ น ได้ ที ่ ห ยิ บ ง่ � ย STIEBEL ELTRON * เครื่ อ งรุ ่ น นี ้ ไ ม่ ร วมท่ อ ชุ ด ใหม่...
  • Page 29: ก�รรั บ ประกั น

    - หั ว ฝั ก บั ว เกิ ด ก�รอุ ด ตั น จ�กสิ ่ ง - ถอดทำ � คว�มสะอ�ด เอ� สกปรกหรื อ หิ น ปู น สิ ่ ง อุ ด ตั น ออก - ELCB ตั ด ก�รทำ � ง�น - กดปุ ่ ม ELCB Reset STIEBEL ELTRON...
  • Page 30 Note STIEBEL ELTRON...
  • Page 31 Note STIEBEL ELTRON...
  • Page 32 Size:A5 Material: White paper 80 g. Plastic bag : 7 x 11 INCH Product code : XG 35 EC (STE) : 230997 / XG 45 EC (STE) : 230998 Part name : Operating instruction XG_EC Rev.02 Part no. 7901-292761...

This manual is also suitable for:

Xg 45 ec

Table of Contents