M10 Suspension Points: Attachment At Any Angle; M10 Suspension Points - Electro-Voice MTS Installation Manual

High output point source
Table of Contents

Advertisement

MTS High Output Point Source
For fully weatherized (FW) models, always coat fasteners with RTV (silicon sealant) prior to
insertion. Make sure a completely watertight seal is achieved and the threads are completely
coated.
5.2.2

M10 Suspension points: Attachment at any angle

Suspension systems can use the hard points at any angle up to 90° to a maximum WLL of:
Safety factor
8:1
10:1
Warning!
This is the WLL for the hardpoints, not for the attached hardware (for example, eyebolts).
!
Always use attachment hardware with adequate WLL calculated for the resultant force angle.
5.2.3

M10 Suspension points:

Suspension frames constructed so that only shear forces act on the hard points can use the
hard points at any angle in the shear plane to a maximum shear force of:
Safety factor
8:1
10:1
Electro-Voice
WLL (lbs)
300
240
Shear force (lbs)
450
360
Installation manual
Designing an MTS array | en
WLL (kg)
136
109
Shear force (kg)
204.1
163.3
2021-09 | V01 | F.01U.386.524