HIKVISION DS-MP3516-RH Installation Manual page 8

Hide thumbs Also See for DS-MP3516-RH:
Table of Contents

Advertisement

HDD
ALM
5
SIM card slot
6
RS-232-1
7
USB interface
8
IPC1 to IPC6
9
100M network interface
1000M network
10
interface
11
Dummy HDD
12
VGA
13
RS-232-2
14
EXT.DEV
15
I/O
16
Power
17
Dummy HDD lock
Digital Video Recorder Installation Guide
Flashing green: Network transmission is normal.
Unlit: No network. Check network cable
connection and IP address.
HDD indicator (HDD):
Solid green: HDD is working normally.
Unlit: No HDD. Check HDD installation.
Alarm indicator
Red: Alarm occurs.
Reserved.
For debugging.
USB 3.0 interface.
6 video inputs. Connects to cameras.
RJ45 10M/100M Ethernet interface.
Connects to switch and network camera.
For HDD installation.
VGA video output interface.
Connects to external devices.
RS-422 communication interface, two-way audio
interface, and CVBS video output.
ALARM IN: Connects to vehicle high/low level
signal as alarm signal source.
ALARM OUT: ALARM OUT n and ALARM OUT n#
are one pair of alarm output interfaces to
control peripheral devices.
3-pin aviation plug for power supply.
Lock/Unlock the dummy HDD.