Troubleshooting Guide; Specifications; Installation - Cobra CPI 1575 Operating Instructions Manual

1500 watt power inverter
Table of Contents

Advertisement

10275_CPI1575_PH3
8/14/07
8:38 AM
Main Icons

Troubleshooting Guide

Operation
Intro
Operation
Customer
Warranty
Troubleshooting Guide
Assistance
Problem/Symptom
Possible Causes
Low output voltage
Overload
No output voltage
Low input

Installation

Notes
voltage
Secondary Icons
No output voltage
Thermal
after prolonged use
shutdown
Notice
Caution
Warning
No output voltage,
High input
"Protect" indicator
voltage
lighted
No output voltage
Short circuit
No output voltage
Inverter
switched off
No power
to inverter
Reverse
DC polarity
Low battery alarm
Poor DC wiring
on all the time
Poor battery
condition
20
Page 20
Main Icons
Operation
Intro
Operation

Specifications

Solution
Continuous output power (1 hour) . . . . . . . . . . . 1500W
Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . 3000W
Reduce the load.
Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88%
Recharge battery.
Installation
Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83%
Check connections
and cable.
No load current draw . . . . . . . . . . . . . . . . < 0.6A (12.6V)
Secondary Icons
Output waveform (resistive load) . . . Modified sine wave
Allow inverter
to cool off.
Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ
Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V
Reduce load,
continuous
USB output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V
Notice
operation input
Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC
current required.
Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V
Improve ventilation;
Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V
Make sure ventilation
Operating temperature range . . . . . . . . . . . . 0°C – 40°C
openings in the
inverter are not
Storage temperature range . . . . . . . . . . . . -40°C – 85°C
obstructed.
Reduce ambient
Protection . . . . . . . . . .Overload, short-circuit, overtemp,
temperature.
Make sure
Notes
the inverter is
connected to
All protection is automatically recovered.
12V battery.
To protect the battery, if the unit needs to be restarted
Check regulation
after low voltage protection, the voltage of DC input
of charging system.
should be above 12V.
Check load for
To extend the life of the fan, it will stop when there is no
proper operation.
load. The speed of the fan increases as the load increases.
Turn inverter on.
The unit is completely insulated in input and output for
added safety.
Check wiring
to inverter.
Observe
correct polarity.
Check connections.
Make sure battery
is fully charged.
Specifications
Customer
Warranty
Assistance
Notes
Caution
Warning
(32°F – 104°F)
(-40°F – 185°F)
reverse polarity, under/over voltage
Nothing Comes Close to a Cobra
®
21