Troubleshooting Guide
Operation
Intro
Operation
Customer
Troubleshooting Guide
Assistance
Problem/
Possible Causes
Symptom
Overload
Low output voltage
Low input
Installation
No output voltage
voltage
Secondary Icons
No output voltage
Thermal
after prolonged use
shutdown
Notice
Caution
No output voltage,
High input
"Protect" indicator
voltage
lighted
No output voltage
Short circuit
No output voltage
Inverter
switched off
No power
to inverter
Reverse
DC polarity
Low battery alarm
Poor DC wiring
on all the time
Poor battery
condition
14
Warranty
•
Solution
Reduce the load.
Recharge battery.
Notes
Check connections
and cable.
Allow inverter
to cool off.
Reduce load,
continuous
Warning
operation input
current required.
Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed.
Reduce ambient
temperature.
Make sure
the inverter is
connected to
12V battery.
Check regulation
of charging system.
Check load for
proper operation.
Turn inverter on.
Check wiring
to inverter.
Observe
correct polarity.
Check
connections.
Make sure battery
is fully charged.
Specifications
Operation
Intro
Operation
Customer
Specifications
Assistance
Continuous output power (1 hour) . . . . . . . . . . . . 800W
Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . 1600W
Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . > 88%
Installation
Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83%
No load current draw . . . . . . . . . . . . . . . . < 0.5A (12.6V)
Secondary Icons
Output waveform (resistive load) . . . Modified sine wave
Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ
Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V
USB output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V
Notice
Caution
Input voltage . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC
Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V
Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V
Operating temperature range . . . . . . . . . . . . . 0°C – 40°C
Storage temperature range . . . . . . . . . . . . -40°C – 85°C
Protection . . . . . . . . . . . Overload, short-circuit, overtemp,
Notes
All protection is automatically recovered.
To protect the battery, if the unit needs to be restarted
after low voltage protection, the voltage of DC input
should be above 12V.
To extend the life of the fan, it will stop when there is no
load. The speed of the fan increases as the load increases.
The unit is completely insulated in input and output for
added safety.
Warranty
Notes
Warning
(32°F – 104°F)
(-40°F – 185°F)
reverse polarity, under/over voltage