Troubleshooting Guide

Operation
Troubleshooting Guide
Problem/Symptom
Possible Causes
Low output voltage
Overload
No output voltage
Low input voltage
No output voltage
Thermal
after prolonged use
shutdown
No output voltage,
High input
"Protect" indicator
voltage
lighted
No output voltage
Short circuit
No power to
Blown fuse
inverter
Low battery alarm
Poor DC wiring
on all the time
Poor battery
condition
14
Solution
Reduce the load.
Recharge battery.
Check connections
and cable.
Allow inverter
to cool off.
Reduce load,
continuous
operation input
current required.
Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed.
Reduce ambient
temperature.
Make sure
the inverter is
connected to
12V battery.
Check regulation
of charging system.
Check load for
proper operation.
Replace fuse.
Check
connections.
Make sure battery
is fully charged.