Cobra PRO Series Owner's Manual

Cobra PRO Series Owner's Manual

Professional grade

Advertisement

1 |
P a g e
©2020 Cobra Electronics Corporation
Version A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRO Series and is the answer not in the manual?

Questions and answers

Chris
May 23, 2025

How do I rest low voltage alarm after it went off. Cobra pro 3000w

1 comments:
Mr. Anderson
May 25, 2025

To reset the low voltage alarm on the Cobra Pro 3000W to the default 11.5 Volts setting:

1. Turn the power inverter on.
2. Press and hold the POWER button for 5 seconds or until the Input Voltage LED turns blue.

This action sets the Low Voltage Alarm back to the default 11.5 Volts.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Cobra PRO Series

  • Page 1 P a g e ©2020 Cobra Electronics Corporation Version A...
  • Page 2: Table Of Contents

    PRO 2500W & 3000W INSTALLATION INSTRUCTIONS ............16 TURNING YOUR INVERTER ON AND OFF ................19 CHANGING THE LOW VOLTAGE ALARM SETTING ..............20 COBRA REMOTE ON/OFF CONTROLLER WITH FAST CHARGE USB .......... 21 OPERATING INDICATORS ....................... 22 OPERATING LIMITS ........................ 23 TROUBLESHOOTING GUIDE ....................
  • Page 3: Introduction

    HOW YOUR POWER INVERTER WORKS The Cobra PRO Power Inverter is a power conversion device that is designed and built to operate from low Voltage DC (Direct Current) power from your vehicle battery and converts it to standard 115 Volt AC (Alternating Current) power like you have in your home.
  • Page 4: Controls And Connections

    CONTROLS AND CONNECTIONS PRO 1500W Features P a g e...
  • Page 5 Digital Display showing Battery Voltage (V), Power in kilowatts (kW), Power in Watts (W) and Error Codes USB-C Fast Charge port (5V/9V/15W)* USB-A Fast Charge port (5V/9V/15W)* Port for Cobra Remote On/Off Controller with Fast Charge USB (Sold Separately)* Power Button Power Cables...
  • Page 6 PRO 2500W and 3000W Features P a g e...
  • Page 7 Digital Display showing Battery Voltage (V), Power in kilowatts (kW), Power in Watts (W) and Error Codes USB-C Fast Charge port (5V/9V/15W)** USB-A Fast Charge port (5V/9V/15W)** Port for Cobra Remote On/Off Controller with Fast Charge USB (Sold Separately)* Power Button Power Cables...
  • Page 8: Important Product/Safety Information

    IMPORTANT PRODUCT /SAFETY INFORMATION Before installing and using your Cobra power inverter, please read these general precautions and warnings. Caution and Warning Statements Special attention must be paid to the CAUTION and WARNING statements in the manual. CAUTION: Statements specify conditions which could cause damage to the unit or other equipment.
  • Page 9: Pentagon Protection

    AC loads (including linear and switching power suppliers used in electronic equipment, transformers and motors). PENTAGON PROTECTION® Cobra power inverters provide five levels of protection: 1. Over-Temperature: Auto-shut off will occur when the safe operating temperature has been exceeded.
  • Page 10: Getting Started

    GETTING STARTED This section provides you with the basic information about the inverter and a few tips before installation. To get started, you will need: 1. A 12 Volt DC battery (i.e. vehicle battery). In order to understand how much current your battery must deliver, divide the number of Watts from your AC appliance or device by 10.
  • Page 11: Mounting The Inverter

    Multiply: AC AMPS X 110 (AC Voltage) = WATTS. This formula yields a close approximation of the continuous load of your appliance. Multiply: WATTS X 2 = Starting load for most appliances, tools and devices. This formula yields a close approximation of the starting load for most appliances.
  • Page 12: Installation Requirements

    INSTALLATION REQUIREMENTS The inverter must be installed in an area that meets all of the following requirements Dry - Do not place in an area where water can drip or splash on the inverter. Cool - Ambient air temperature should be between 30°F and 105°F (0°C and 40°C). The cooler the better.
  • Page 13: Pro 1500W Installation Instructions

    PRO 1500W INSTALLATION INSTRUCTIONS: These instructions are specific for Negative Ground 12 Volt Systems. In a Negative Ground System, the negative terminal (Black) is connected to the chassis or engine housing. CAUTION: If you are not familiar with 12 Volt high current wiring, please contact a professional installer for assistance.
  • Page 14 Thoroughly ventilate the battery compartment before making this connection. All power connections to your Cobra inverter must be Positive to Positive and Negative to Negative. CAUTION: Electrical installations must meet local and national wiring codes, and should be performed by a qualified electrician.
  • Page 15 PRO 1500W INSTALLATION 15 | P a g e...
  • Page 16: Pro 2500W & 3000W Installation Instructions

    PRO 2500W & 3000W INSTALLATION INSTRUCTIONS These instructions are specific for Negative Ground 12 Volt Systems. In a Negative Ground System, the negative terminal (Black) is connected to the chassis or engine housing. CAUTION: If you are not familiar with 12 Volt high current wiring, please contact a professional installer for assistance.
  • Page 17 Do not make this connection in the presence of flammable fumes. Explosion or fire may result. Thoroughly ventilate the battery compartment before making this connection. All power connections to your Cobra inverter must be Positive to Positive and Negative to Negative.
  • Page 18 PRO 2500W AND 3000W INSTALLATION 18 | P a g e...
  • Page 19: Turning Your Inverter On And Off

    TURNING YOUR POWER INVERTER ON AND OFF Be sure to have your power inverter properly mounted and installed before attempting to turn it on (see page 11). PRO1500W/2500W POWER INVERTER BASIC OPERATION Press the POWER button to turn on your inverter. When powered on the Input Voltage LED is green.
  • Page 20: Changing The Low Voltage Alarm Setting

    From the factory the inverter defaults to a 11.5 Volt Low Voltage Alarm setting for professional trucks. If using a Cobra Pro Power Inverter with other vehicle types such as a car, van or RV, run time can be extended by changing the default Low Voltage Alarm to the alternate setting at 10.5 Volts.
  • Page 21: Cobra Remote On/Off Controller With Fast Charge Usb

    COBRA REMOTE ON/OFF CONTROLLER WITH FAST CHARGE USB The Cobra Remote On/Off Controller with Fast Charge USB is included with the Cobra PRO 3000W Power Inverter. All PRO Inverters come equipped with an RJ-45 jack labeled "REMOTE" for compatibility with the Cobra Remote On/Off Controller with Fast Charge USB to allow you to conveniently turn the inverter ON and OFF from anywhere inside your vehicle as well fast charge your devices at the same time.
  • Page 22: Operating Indicators

    OPERATING INDICATORS Indicators on the power inverter show the unit’s power status and alarms for conditions that could cause it to shut down. Power on – The Voltage Input and Power Output indicators automatically toggle between input and output values at three-second intervals. The three LEDs indicate the mode the meter is in and the three digits indicate the voltage or power value.
  • Page 23: Operating Limits

    OPERATING LIMITS Power Output Your PRO Series power inverter can operate on its full rated output for about 60 minutes. The inverter must cool for 15 minutes before it can resume operation at maximum output. The inverter will operate most AC loads within its power rating. Some induction motors used in freezers, pumps, and other motor-operated equipment require very high surge currents to start.
  • Page 24: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Problem/Symptom Possible Causes Low output voltage Overload Reduce the load. Recharge ba ery. Check No output voltage Low input voltage connec ons and cable. No output voltage Thermal shutdown Allow inverter to a er prolonged use cool off. Reduce load, con nuous opera on input current required.
  • Page 25: Specifications

    DC input terminals. Be sure vents and fans are free of dust or debris. Product Service For any questions about operating or installing this new Cobra product, please go to www.cobra.com 25 | P a g e...
  • Page 26: Remote On/Off Controller With Fast Charge Usb Operating Instructions

    Works with Cobra Power Inverters: CPI400PSW, CPI500W, CPI1500W, CPI2500W and CPI3000W. Cobra and the snake design are registered trademarks of Cobra Electronics Corporation, USA. ® Cobra Electronics Corporation™ is a trademark of Cobra Electronics Corporation, USA. Other trademarks and trade names are those of their respective owners.
  • Page 27 Remote Controller Features LCD Display Power Button Fast Charge USB-C* Fast Charge USB-A* Flush Mounts Clip Mount for Clip Mounting Option Keyhole Mount RJ-45 Remote Control Cable Jack RJ-45 Remote Control Cable Clip Mont M3.5 Screws * = Fast Charge works only on devices capable of supporting a charge up to 10W 27 | P a g e...
  • Page 28 4-Point Mounting System Whether you own a standard vehicle, RV, Professional Truck, or Camper, Cobra gives you (4) Mounting options to remotely turn your inverter on and off as well as charge your devices from anywhere in your vehicle: See Mounting...
  • Page 29 29 | P a g e...
  • Page 30 REMOTE DISPLAY MESSAGING Standby Mode When you plug in the Remote On/Off Controller with Fast Charge USB and press the power button to ON, the display will show AC Output (Watts being used) and the DC Input (Battery Volts). The images below show the messaging on the LCD display when the remote is turned ON or OFF.
  • Page 31 DC Input High Voltage Alarm AC Output Short The alarm will sound when the battery is at 15.0V. The alarm will sound and the inverter will shut down when the AC output is shorted. ………………………………………………………………………………………………………………………………………………………………….. AC Output Overload Inverter Over Temperature The alarm will sound and the inverter will shut down The alarm will sound and the inverter will AC output exceeds the inverter limits.
  • Page 32 Remote is being used with Display Error messages are only supported by an alarm but no Error models that do not support PRO Series inverters. CPI500W and CPI400PSW messages are showing this function Models do not support error messages on the LCD...
  • Page 33: Warranty & Trademark Acknowledgement

    You must pay any initial shipping charges required to ship the product for warranty service, but the return charges will be at Cobra’s expense, if the product is repaired or replaced under warranty. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state.
  • Page 34: Mounting Template

    This template should measure 3.35". Please ensure that this measurement is checked on your print-out for accuracy before making your cuts and installing. 34 | P a g e...

This manual is also suitable for:

Pro 1500wPro 2500wPro 3000wCpi1500wCpi2500wCpi3000w

Table of Contents

Save PDF