Download Print this page

Sony Alpha E 4/PZ 18-110 G OSS Service Manual page 69

Advertisement

Preparations of Using a Camera (General E-mount
Interchangeable Lens Digital Camera)
Equipment
• Camera (General E-mount interchangeable lens digital camera)
Preparation
1. Attach the E-mount attachment to the A-mount attachment and
install them to the flange back tester.
Note 1: Confi gure the setting of a camera attached to the E-
mount attachment as follows.
• Focus Mode: Manual Focus
• Shake Compensation: OFF
• Aperture: Open
2. Attach the extension jig (47.00 mm) to the objective lens (10x)
to install it to the flange back tester.
3. Attach the checking lens to the flange back tester as shown in
the following figure, and set the 1000 mm collimator.
Checking lens
1000 mm collimator
E-mount Attachment
4. Turn the focus ring of the checking lens while observing the
microscope and stop it at the position where the chart image is
in focus.
Extension Jig (47.00 mm)
FB Tester Stand
Camera Table
200×200
Camera
(General E-mount
interchangeable lens
digital camera)
5-6
Preparations of Using a B-L Control Box
Equipment
• Personal Computer (See Note 1)
• B-L Control Box (Supplied with D-sub 15-pin cable)
• AC cable (Sold on the market)
• RS-232C Cable (D-sub 9-pin (Male with securing screws), D-sub
9-pin (Female with securing screws)) Straight type (Sold on the
market)
• USB to serial cable (D-sub 9-pin (Male)) (Sold on the market)
• Lens adjustment program (BLG-TestProgramV[][][].exe) (See
Note 2)
Note 1: Personal computer must have the condition that Windows
Vista/7 runs normally and USB is connectable.
Note 2: For adjustment of the SELP18110G, prepare a version 1.0.0.1
or higher of the BLG-TestProgram.
Preparation
1. Attach the E-mount attachment to the A-mount attachment and
install them to the flange back tester.
2. Attach the extension jig (47.00 mm) to the objective lens (10x)
to install it to the flange back tester.
3. Attach the checking lens to the flange back tester as shown in
the following figure, and set the 1000 mm collimator.
Checking lens
1000 mm collimator
E-mount Attachment
B-L Control Box
D-sub 15-pin
D-sub 9-pin:
cable
Male
AC Cable
D-sub 9-pin: Female
RS-232C Cable
4. Install the BLG-TestProgram in the following procedure.
(1) Download the file "BLG-TestProgramV[][][].zip", save and
extract it.
(2) Save "BLG-TestProgramV[][][].exe" in an arbitrary folder.
SELP18110G
Extension Jig (47.00 mm)
FB Tester Stand
Camera Table
200×200
Personal computer
USB to Serial Cable
– Continued on next page –

Advertisement

loading

This manual is also suitable for:

Alpha e pz 18-110mm f4 g ossSelp18110g